A Multi-Time-Step Transmission Line Interface for Power Hardware-in-the-Loop Simulators

Research output: Contribution to journalJournal Articlepeer-review

24 Citations (Scopus)

Abstract

Developing a general and stable numerical interface for power hardware-in-the-loop (PHIL) applications is a major challenge. This paper proposes a stable, robust and precise implementation of a multi-time-step interface for a PHIL simulator based on the Bergeron transmission line model (BTLM). Two limitations of the transmission-line-based interface were identified, and remedial strategies were formulated in order to ensure that the interface was compatible with the PHIL application. Stability and passivity analyses were then conducted on the resulting interface to verify its performance. The proposed interface was implemented in an experimental 3-kVA PHIL setup, using a custom-made switching power amplifier (PA). Multiple tests were performed in order to demonstrate the stability and accuracy of the closed-loop system under a wide range of operating conditions and with various devices under test (DUTs). Experimental results were obtained from islanding tests involving different simulated load configurations and solar inverter responses to network disturbance while operating in a closed-loop configuration.

Original languageEnglish
Article number8839607
Pages (from-to)539-548
Number of pages10
JournalIEEE Transactions on Energy Conversion
Volume35
Issue number1
DOIs
Publication statusPublished - Mar 2020

!!!Keywords

  • Bergeron transmission line model
  • FPGA
  • digital simulation
  • discrete-time systems
  • energy conversion
  • interface algorithm
  • modeling
  • power hardware-in-the-loop simulation
  • real-time systems
  • stability analysis

Fingerprint

Dive into the research topics of 'A Multi-Time-Step Transmission Line Interface for Power Hardware-in-the-Loop Simulators'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.

Cite this