Skip to main navigation Skip to search Skip to main content

A novel topology for process variation-tolerant piezoelectric micromachined ultrasonic transducers

  • École de technologie supérieure
  • Université du Québec à Montréal

Research output: Contribution to journal › Journal Article › peer-review

15 Citations (Scopus)

Abstract

This paper presents a novel architecture for piezoelectric micromachined ultrasonic transducers (PMUT) allowing for a drastic reduction in the impact of process variations on the accuracy of the resonant frequency. At the core of this new topology is a toroidal anchoring technique. Measurement results show that inter- and intra-die resonant frequency standard variations can be reduced from 101 kHz to 23 kHz and from 20 kHz to 5.9 kHz, respectively, by using the method proposed in this paper, showcasing devices fabricated using the PiezoMUMPs commercial fabrication technology. From the 16 chips that have been fabricated, each holding 12 PMUT devices of two different topologies, resonant frequency results are presented and analyzed to assess the effectiveness of the proposed approach. In addition, as a proof of concept, the fabricated PMUT are demonstrated to perform distance ranging measurements.

Original languageEnglish
Article number8513882
Pages (from-to)1204-1212
Number of pages9
JournalJournal of Microelectromechanical Systems
Volume27
Issue number6
DOIs
Publication statusPublished - Dec 2018

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 9 - Industry, Innovation, and Infrastructure
    SDG 9 Industry, Innovation, and Infrastructure

Keywords

  • MEMS
  • PMUT
  • Piezoelectric ultrasonic transducers
  • frequency
  • microfabrication
  • process variation
  • ranging measurements
  • variability

ASJC Scopus subject areas

  • Mechanical Engineering
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'A novel topology for process variation-tolerant piezoelectric micromachined ultrasonic transducers'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.

Cite this