A system in package based on a piezoelectric micromachined ultrasonic transducer matrix for ranging applications

  • Université du Québec à Chicoutimi
  • Université du Québec à Montréal

Research output: Contribution to journal › Journal Article › peer-review

6 Citations (Scopus)

Abstract

This paper proposes a system in package (SiP) for ultrasonic ranging composed of a 4 × 8 matrix of piezoelectric micromachined ultrasonic transducers (PMUT) and an interface integrated circuit (IC). The PMUT matrix is fabricated using the PiezoMUMPS process and the IC is implemented in the AMS 0.35 µm technology. Simulation results for the PMUT are compared to the measurement results, and an equivalent circuit has been derived to allow a better approximation of the load of the PMUT on the IC. The control circuit is composed of a high-voltage pulser to drive the PMUT for transmission and of a transimpedance amplifier to amplify the received echo. The working frequency of the system is 1.5 MHz.

Original languageEnglish
Article number2590
JournalSensors
Volume21
Issue number8
DOIs
Publication statusPublished - 2 Apr 2021

Keywords

  • High voltage pulser
  • Piezoelectric micromachined ultrasonic transducers (PMUT)
  • Regulated cascode (RGC)
  • Transimpedance amplifier (TIA)

ASJC Scopus subject areas

  • Analytical Chemistry
  • Information Systems
  • Atomic and Molecular Physics, and Optics
  • Biochemistry
  • Instrumentation
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'A system in package based on a piezoelectric micromachined ultrasonic transducer matrix for ranging applications'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.

Cite this