Abstract
During thoracic operations, surgical staplers resect cancerous tumors and seal the spared lung. However, post-operative air leaks are undesirable clinical consequences: staple legs wound lung tissue. Subsequent to this trauma, air leaks from lung tissue into the pleural space. This affects the lung's physiology and patients' recovery. The objective is to biomechanically and visually characterize porcine lung tissue with and without staples in order to gain knowledge on air leakage following pulmonary resection. Therefore, a syringe pump filled with air inflates and deflates eleven porcine lungs cyclically without exceeding 10 cmH2O of pressure. Cameras capture stereo-images of the deformed lung surface at regular intervals while a microcontroller simultaneously records the alveolar pressure and the volume of air pumped. The raw images are then used to compute tri-dimensional displacements and strains with the Digital Image Correlation method (DIC). Air bubbles originated at staple holes of inner row from exposed porcine lung tissue due to torn pleural on costal surface. Compared during inflation, left upper or lower lobe resections have similar compliance (slope of the pressure vs volume curve), which are 9% lower than healthy lung compliance. However, lower lobes statistically burst at lower pressures than upper lobes (p-value<0.046) in ex vivo conditions confirming previous clinical in vivo studies. In parallel, the lung deformed mostly in the vicinity of staple holes and presented maximum shear strain near the observed leak location. To conclude, a novel technique DIC provided concrete evidence of the post-operative air leaks biomechanics. Further studies could investigate causal relationships between the mechanical parameters and the development of an air leak.
| Original language | English |
|---|---|
| Article number | 104883 |
| Journal | Journal of the Mechanical Behavior of Biomedical Materials |
| Volume | 125 |
| DOIs | |
| Publication status | Published - Jan 2022 |
| Externally published | Yes |
Keywords
- Air leak
- Digital imaging correlation
- Lung biomechanics
- Pulmonary resection
- Staple
ASJC Scopus subject areas
- Biomaterials
- Biomedical Engineering
- Mechanics of Materials
Fingerprint
Dive into the research topics of 'Air leaks: Stapling affects porcine lungs biomechanics'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver