Skip to main navigation Skip to search Skip to main content

Binocular approach to 3D pose measurement with auto-calibration

  • University of Leoben

Research output: Contribution to Book/Report types › Contribution to conference proceedings › peer-review

Abstract

This paper presents the design, implementation and test of a binocular measurement device for the determination of relative pose. The instrument is designed for the use with large plant parts and machinery in very harsh environments as encountered in off-shore hydrocarbon exploration, mining and tunnelling. The device is equipped with a fall-back monocular measurement procedure. This permits measurement despite the failure of one camera; however, with reduced accuracy. An algebraic formulation and derivation of the equations required to implement the auto-calibration and measurement procedure are presented. The laboratory test environment is presented, as are the results of extensive testing, which can be as summarized as follows: the root mean square measured positional error is ξx,y,z = [0.283, 0.351, 4.809] mm and the rotational measurement error of ξφ= 0.106 when the measurement is performed at distances up to approximately 3.95 m.

Original languageEnglish
Title of host publication2015 IEEE International Instrumentation and Measurement Technology Conference - The "Measurable" of Tomorrow
Subtitle of host publicationProviding a Better Perspective on Complex Systems, I2MTC 2015 - Proceedings
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages881-886
Number of pages6
ISBN (Electronic)9781479961139
DOIs
Publication statusPublished - 6 Jul 2015
Externally publishedYes
Event2015 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2015 - Pisa, Italy
Duration: 11 May 2015 → 14 May 2015

Publication series

NameConference Record - IEEE Instrumentation and Measurement Technology Conference
Volume2015-July
ISSN (Print)1091-5281

Conference

Conference2015 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2015
Country/TerritoryItaly
CityPisa
Period11/05/15 → 14/05/15

Fingerprint

Dive into the research topics of 'Binocular approach to 3D pose measurement with auto-calibration'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.

Cite this