Abstract
Windows generally have the lowest temperature index in current building types, and will consequently be the primary location for interior surface condensation. Surface temperatures can easily be calculated using thermal finite-element models, but these generally omit the effect of convection in the windows and the window-wall interface. Hence, there is a need to determine if specific interface details provide potential for condensation on the window components in which air leakage paths may be prominent. The article reports on a laboratory evaluation of condensation risk assessment in a hotbox with varying pressure differences and the introduction of deficiencies. It was concluded that the effect of the type of insulation in the window-wall interface was very low for isobaric boundary conditions, whereas it has a significant effect when pressure differences are applied.
| Original language | English |
|---|---|
| Pages (from-to) | 35-56 |
| Number of pages | 22 |
| Journal | Journal of Building Physics |
| Volume | 36 |
| Issue number | 1 |
| DOIs | |
| Publication status | Published - Jul 2012 |
| Externally published | Yes |
!!!Keywords
- Condensation
- airtightness
- window frames
Fingerprint
Dive into the research topics of 'Condensation risk assessment on box windows: The effect of the window-wall interface'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver