Skip to main navigation Skip to search Skip to main content

Debonding of coin-shaped osseointegrated implants: Coupling of experimental and numerical approaches

  • Yoann Hériveaux
  • , Sophie Le Cann
  • , Katharina Immel
  • , Elsa Vennat
  • , Vu Hieu Nguyen
  • , Vladimir Brailovski
  • , Patrick Karasinski
  • , Roger A. Sauer
  • , Guillaume Haïat
  • Université Paris-Saclay
  • UMR CNRS 8208
  • RWTH Aachen University
  • Université Paris-Est Créteil
  • Gdańsk University of Technology
  • Indian Institute of Technology Guwahati

Research output: Contribution to journal › Journal Article › peer-review

1 Citation (Scopus)

Abstract

While cementless implants are now widely used clinically, implant debonding still occur and is difficult to anticipate. Assessing the biomechanical strength of the bone–implant interface can help improving the understanding of osseointegration phenomena and thus preventing surgical failures. A dedicated and standardized implant model was considered. The samples were tested using a mode III cleavage device to assess the mechanical strength of the bone-implant interface by combining experimental and numerical approaches. Four rough (Sa = 24.5 μm) osseointegrated coin-shaped implants were left in sheep cortical bone during 15 weeks of healing time. Each sample was experimentally rotated at 0.03°/sec until complete rupture of the interface. The maximum values of the torque were comprised between 0.48 and 0.72 N m, while a significant increase of the normal force from 7-12 N to 31–43 N was observed during the bone-implant interface debonding, suggesting the generation of bone debris at the bone-implant interface. The experimental results were compared to an isogeometric finite element model describing the adhesion and debonding phenomena through a modified Coulomb's law, based on a varying friction coefficient to represent the transition from an unbroken to a broken bone-implant interface. A good agreement was found between numerical and experimental torques, with numerical friction coefficients decreasing from 8.93 to 1.23 during the bone-implant interface rupture, which constitutes a validation of this model to simulate the debonding of an osseointegrated bone-implant interface subjected to torsion.

Original languageEnglish
Article number105787
JournalJournal of the Mechanical Behavior of Biomedical Materials
Volume141
DOIs
Publication statusPublished - May 2023

Keywords

  • Adhesion
  • Bone-implant interface
  • Finite element modeling
  • Friction
  • Osseointegration

ASJC Scopus subject areas

  • Biomaterials
  • Biomedical Engineering
  • Mechanics of Materials

Fingerprint

Dive into the research topics of 'Debonding of coin-shaped osseointegrated implants: Coupling of experimental and numerical approaches'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.

Cite this