Skip to main navigation Skip to search Skip to main content

Does radiographic beam angle affect the radiocapitellar ratio measurement of subluxation in the elbow? Elbow

  • Fannie McCann
  • , Fanny Canet
  • , Emilie Sandman
  • , Yvan Petit
  • , Dominique M. Rouleau
  • University of Montreal
  • Research Center - Hôpital du Sacré-Coeur de Montréal

Research output: Contribution to journal › Journal Article › peer-review

6 Citations (Scopus)

Abstract

Background: Radial head alignment is the key to determine elbow reduction after treatment of subluxations or Monteggia fractures. The radiocapitellar ratio (RCR) quantifies the degree of subluxation, by evaluating radial head alignment with the capitellum of the humerus; this ratio is reproducible when measured on true lateral radiographs of nonsubluxated elbows. However, the impact of beam angulation on RCR measurement is unknown. Questions/purposes: Our hypotheses were that the RCR of the nonsubluxated elbow would remain in the normal range as the beam angle changed and that the RCR variability would increase for the subluxated elbow with small deviations in the beam angle. Methods: Radiographs were taken of six healthy cadaveric extremities using beam angles ranging from -20 to 20 along the inferosuperior axis and from -20 to 20 along the dorsoventral axis. The same views then were taken of the six arms with anterior radiocapitellum subluxation followed by posterior radiocapitellum subluxation. RCRs were measured by one observer. As a reference value, the RCR was measured in the 0 to 0 position and the difference between each RCR in a nonreference position was subtracted from each RCR reference to obtain the delta-RCR. An ANOVA was performed to assess the main and interactive effects on the RCR measured in each C-arm position compared with the RCR measured on a true lateral radiograph. Results: The RCR remained in the normal range even as the beam angle of the C-arm varied between -20 and 20. The position of the beam did not affect the RCR in anteriorly subluxated elbows (p = 0.777), whereas RCR variation increased especially in the presence of posterior radial head subluxation when the C-arm position was 10 or more out of plane (p = 0.006). The inferosuperior malposition of the C-arm had a greater impact on quantification of radial head alignment measurement. Despite that, the RCR measurement is reliable in reduced and subluxated elbows on lateral radiographs with a C-arm position deviation of as much as 20. Conclusions: Identification of a subluxated elbow could be made on any lateral radiograph with a beam angulation deviation of as much as 20. This suggests that the RCR is a useful diagnostic tool for clinical and research purposes, although for subluxated elbows, it is important to pay careful attention to the inferosuperior position of the C-arm.

Original languageEnglish
Pages (from-to)2556-2562
Number of pages7
JournalClinical Orthopaedics and Related Research
Volume471
Issue number8
DOIs
Publication statusPublished - Aug 2013
Externally publishedYes

ASJC Scopus subject areas

  • Surgery
  • Orthopedics and Sports Medicine

Fingerprint

Dive into the research topics of 'Does radiographic beam angle affect the radiocapitellar ratio measurement of subluxation in the elbow? Elbow'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.

Cite this