Abstract

AIM: To evaluate the effect of different elbow and forearm positions on radiocapitellar alignment. METHODS: Fifty-one healthy volunteers were recruited and bilateral elbow radiographs were taken to form a radiologic database. Lateral elbow radiographs were taken with the elbow in five different positions: Maximal extension and forearm in neutral, maximal flexion and forearm in neutral, elbow at 90° and forearm in neutral, elbow at 90° and forearm in supination and elbow at 90° and forearm in pronation. A goniometer was used to verify the accuracy of the elbow's position for the radiographs at a 90° angle. The radiocapitellar ratio (RCR) measurements were then taken on the collected radiographs using the SliceOmatic software. An orthopedic resident performed the radiographic measurements on the 102 elbows, for a total of 510 lateral elbow radiographic measures. ANOVA paired t -tests and Pearson coefficients were used to assess the differences and correlations between the RCR in each position. RESULTS: Mean RCR values were -2% ± 7% (maximal extension), -5% ± 9% (maximal flexion), and for elbow at 90° and forearm in neutral -2% ± 5%, supination 1% ± 6% and pronation 1% ± 5%. ANOVA analyses demonstrated significant differences between the RCR in different elbow and forearm positions. Paired t -tests confirmed significant differences between the RCR at maximal flexion and flexion at 90°, and maximal extension and flexion. The Pearson coefficient showed significant correlations between the RCR with the elbow at 90° - maximal flexion; the forearm in neutralsupination; the forearm in neutral-pronation. CONCLUSION: Overall, 95% of the RCR values are included in the normal range (obtained at 90° of flexion) and a value outside this range, in any position, should raise suspicion for instability.

Original languageEnglish
Pages (from-to)117-122
Number of pages6
JournalWorld Journal of Orthopedics
Volume7
Issue number2
DOIs
Publication statusPublished - 2016
Externally publishedYes

Keywords

  • Elbow
  • Elbow dislocation
  • Elbow subluxation
  • Radiocapitellar ratio

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Fingerprint

Dive into the research topics of 'Effect of elbow position on radiographic measurements of radio-capitellar alignment'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.

Cite this