Skip to main navigation Skip to search Skip to main content

Estimating evaporation rates and contaminant air concentrations due to small spills of non-ideal aqueous organic solvent mixtures in a controlled environment

  • Spéro Franck Abattan
  • , Patrick Eddy Ryan
  • , Jérôme Lavoué
  • , Stéphane Hallé
  • , Ali Bahloul
  • , Daniel Drolet
  • , Maximilien Debia
  • University of Montreal
  • Institut de recherche Robert-Sauvé en santé et en sécurité du travail

Research output: Contribution to journal › Journal Article › peer-review

2 Citations (Scopus)

Abstract

Although small spills of non-ideal organic solvent mixtures are ubiquitous undesirable events in occupational settings, the potential risk of exposure associated with such scenarios remains insufficiently investigated. This study aimed to examine the impact of non-ideality on evaporation rates and contaminant air concentrations resulting from small spills of organic solvent mixtures. Evaporation rate constants alphas (α) were experimentally measured for five pure solvents using a gravimetric approach during solvent evaporation tests designed to simulate small spills of solvents. Two equations were used for estimating contaminants’ evaporation rates from aqueous mixtures assuming either ideal or non-ideal behavior based on the pure-chemical alpha values. A spill model also known as the well-mixed room model with exponentially decreasing emission rate was used to predict air concentrations during various spill scenarios based on the two sets of estimated evaporation rates. Model predictive performance was evaluated by comparing the estimates against real-time concentrations measured for the same scenarios. Evaluations for 12 binary non-ideal aqueous mixtures found that the estimated evaporation rates accounting for the correction by the activity coefficients of the solvents (median = 0.0318 min−1) were higher than the evaporation rates estimated without the correction factor (median = 0.00632 min−1). Model estimates using the corrected evaporation rates reasonably agreed with the measured values, with a median predicted peak concentrations-to-measured peak concentrations ratio of 0.92 (0.81 to 1.32) and a median difference between the predicted and the measured peak times of −5 min. By contrast, when the non-corrected evaporation rates were used, the median predicted peak concentrations-to-measured peak concentrations ratio was 0.31 (0.08 to 0.75) and the median difference between the predicted and the measured peak times was +33 min. Results from this study demonstrate the importance of considering the non-ideality effect for accurately estimating evaporation rates and contaminant air concentrations generated by solvent mixtures. Moreover, this study is a step further in improving knowledge of modeling exposures related to small spills of organic solvent mixtures.

Original languageEnglish
Pages (from-to)95-108
Number of pages14
JournalJournal of Occupational and Environmental Hygiene
Volume20
Issue number2
DOIs
Publication statusPublished - 2023

Keywords

  • Aqueous mixture
  • IHMOD
  • decreasing emission model
  • evaporation rate
  • exposure assessment
  • non-ideality
  • small spills
  • solvent

ASJC Scopus subject areas

  • Public Health, Environmental and Occupational Health

Fingerprint

Dive into the research topics of 'Estimating evaporation rates and contaminant air concentrations due to small spills of non-ideal aqueous organic solvent mixtures in a controlled environment'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.

Cite this