TY - GEN
T1 - Fatigue properties of superelastic Ti-Ni filaments used in braided cables for bone fixation
AU - Yannick, Baril
AU - Vladimir, Brailovski
AU - Patrick, Terriault
PY - 2008
Y1 - 2008
N2 - Superelastic 0.1mm diameter Ti-Ni filaments are used to manufacture braided orthopedic cable for bone fixation. Biomechanical conditions for this application generally have a cyclic nature, and therefore it becomes important to evaluate the influence of the installation (mean) strain on the fatigue life of these filaments. Uniaxial tension cyclic testing of Ti-Ni filaments is performed in a water bath at 37°C with a 2Hz frequency of to 100 000 cycles. Strain-controlled testing conditions are as follows: alternating strain magnitude varies between 0.64 and 3.64% with mean strain range between 1.32 and 7.1%. Based on the premises that the minimum strain should be high enough to prevent any loss of tension in the tested specimen and that the maximum strain should not bring the specimen to failure during the first loading cycle, the total strain magnitude is encompassed between 0.68 and 8.94%. The results obtained provide a better understanding of the impact mean strain has on the fatigue life of superelastic Ti-Ni alloys.
AB - Superelastic 0.1mm diameter Ti-Ni filaments are used to manufacture braided orthopedic cable for bone fixation. Biomechanical conditions for this application generally have a cyclic nature, and therefore it becomes important to evaluate the influence of the installation (mean) strain on the fatigue life of these filaments. Uniaxial tension cyclic testing of Ti-Ni filaments is performed in a water bath at 37°C with a 2Hz frequency of to 100 000 cycles. Strain-controlled testing conditions are as follows: alternating strain magnitude varies between 0.64 and 3.64% with mean strain range between 1.32 and 7.1%. Based on the premises that the minimum strain should be high enough to prevent any loss of tension in the tested specimen and that the maximum strain should not bring the specimen to failure during the first loading cycle, the total strain magnitude is encompassed between 0.68 and 8.94%. The results obtained provide a better understanding of the impact mean strain has on the fatigue life of superelastic Ti-Ni alloys.
KW - Medical device
KW - Superelasticity
KW - Ti-Ni shape memory alloys
UR - https://www.scopus.com/pages/publications/62449274593
M3 - Contribution to conference proceedings
AN - SCOPUS:62449274593
SN - 9783908158141
T3 - CIMTEC 2008 - Proceedings of the 3rd International Conference on Smart Materials, Structures and Systems - Biomedical Applications of Smart Materials, Nanotechnology and Micro/Nano Engineering
SP - 235
EP - 240
BT - CIMTEC 2008 - Proceedings of the 3rd International Conference on Smart Materials, Structures and Systems - Biomedical Applications of Smart Materials, Nanotechnology and Micro/Nano Engineering
T2 - 3rd International Conference on Smart Materials, Structures and Systems - Biomedical Applications of Smart Materials, Nanotechnology and Micro/Nano Engineering, CIMTEC 2008
Y2 - 8 June 2008 through 13 June 2008
ER -