Abstract
The authors provide a novel hysteresis control method for the SPUC inverter in this paper. The suggested system, which consist of the SPUC inverter and the balancing algorithm can offer eleven levels at output voltage using only seven switches, a closed loop is applied to maintain capacitors voltage at desired values, another hysteresis control that ensures capacitors voltage self-balancing is implemented in open loop which result in the proposed SPUC9 inverter .No voltage sensor or filtering is needed, as a consequence the inverter and installation expenses are kept to a minimum. The authors utilized MATLAB/Simulink environment to simulate the proposed converters. Simulation results prove all the concepts given in this paper. Total harmonic distortion remains reduced and depends on the hysteresis bandwidth.
| Original language | English |
|---|---|
| Pages (from-to) | 1345-1354 |
| Number of pages | 10 |
| Journal | Indonesian Journal of Electrical Engineering and Computer Science |
| Volume | 28 |
| Issue number | 3 |
| DOIs | |
| Publication status | Published - Dec 2022 |
| Externally published | Yes |
Keywords
- Hystetesis control
- Neutral point clamped
- Packed-U-cell
- Split packed-U-cell
- Total harmonic distortion
ASJC Scopus subject areas
- Signal Processing
- Information Systems
- Hardware and Architecture
- Computer Networks and Communications
- Control and Optimization
- Electrical and Electronic Engineering
Fingerprint
Dive into the research topics of 'Hysteresis control of the new split-packed-U-cell inverter'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.Cite this