Abstract
This paper introduces an enhanced commutation method applied to the indirect matrix converter topology. It is based on the detection of the load current polarity so as to cancel the turn-on delay times of the load-side converter's switches. The proposed method allows the grid-side converter devices to commutate at zero current with larger time interval widths provided for this safe commutation. Moreover, it has been shown through experimental results, carried out on a laboratory prototype of the matrix converter, that a substantial improvement of line current total harmonic distortion is achieved.
| Original language | English |
|---|---|
| Article number | 6862009 |
| Pages (from-to) | 671-679 |
| Number of pages | 9 |
| Journal | IEEE Transactions on Industrial Electronics |
| Volume | 62 |
| Issue number | 2 |
| DOIs | |
| Publication status | Published - 1 Feb 2015 |
ASJC Scopus subject areas
- Control and Systems Engineering
- Electrical and Electronic Engineering
Fingerprint
Dive into the research topics of 'Indirect Matrix Converters' Enhanced Commutation Method'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS