Skip to main navigation Skip to search Skip to main content
36 Citations (Scopus)

Abstract

A lack of observed data can lead to significant discrepancy between estimated and actual fatigue reliability. In this study, the load spectrum derived from the strain measurements and operation history of a hydroelectric turbine are used to identify the information necessary to avoid major bias in the estimated fatigue reliability of such structure. Our results demonstrate that a limited number of parameters need to be considered. Any further simplifications may lead to major reliability estimate discrepancies. Furthermore, we observe that the parameters which influence initial reliability hide the influence of other parameters on the reliability failure rate associated with the structure's life expectancy. We conclude that a typical sensitivity analysis made on parameter values needs to be complemented with a sensitivity study on the chosen assumptions in order to properly evaluate the risks associated with the operation of hydroelectric turbines.

Original languageEnglish
Pages (from-to)1-8
Number of pages8
JournalStructural Safety
Volume50
DOIs
Publication statusPublished - Sept 2014

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 7 - Affordable and Clean Energy
    SDG 7 Affordable and Clean Energy

!!!Keywords

  • High Cycle Fatigue (HCF)
  • Hydroelectric turbine
  • Load spectrum
  • Reliability

Fingerprint

Dive into the research topics of 'Influence of load spectrum assumptions on the expected reliability of hydroelectric turbines: A case study'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.

Cite this