Skip to main navigation Skip to search Skip to main content

Investigation on the low frequency dielectric response of ground-wall insulation of rotating machine windings

  • Eric David
  • , Rémi Taghizad
  • , Laurent Lamarre
  • , D. N. Nguyen
  • EXACT
  • Hydro-Quebec

Research output: Contribution to journal › Conference article › peer-review

10 Citations (Scopus)

Abstract

In order to assess the quality of stator winding insulation, laboratory and field instruments measuring the charge and discharge currents flowing through rotating machine ground-wall winding insulation were developed. These instruments apply a dc voltage step during a variable charging time at various voltage levels followed by a discharge step during which the insulating dielectric is shorted to ground. The current is continuously monitored during both the charge and the discharge steps. An investigation was conducted for epoxy-mica insulation systems in laboratory as well as on complete windings in the field.

Original languageEnglish
Pages (from-to)157-160
Number of pages4
JournalConference on Electrical Insulation and Dielectric Phenomena (CEIDP), Annual Report
Publication statusPublished - 2003
Event2003 Annual Report: Conference on Electrical Insulation and Dieletric Phenomena - Albuquerque, NM, United States
Duration: 19 Oct 2003 → 22 Oct 2003

ASJC Scopus subject areas

  • Building and Construction
  • Industrial and Manufacturing Engineering
  • Electrical and Electronic Engineering

Fingerprint

Dive into the research topics of 'Investigation on the low frequency dielectric response of ground-wall insulation of rotating machine windings'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.

Cite this