Skip to main navigation Skip to search Skip to main content

Learning a tissue invariant ultrasound speckle decorrelation model

  • McGill University

Research output: Contribution to Book/Report types › Contribution to conference proceedings › peer-review

4 Citations (Scopus)

Abstract

In untracked freehand 3D ultrasound (US), image content can be used to infer the trajectory of the transducer without a position tracking device. The nominal relationship between image correlation and elevational separation is established from controlled scans of a speckle phantom and used to determine out-of-plane motion. Unfortunately, this nominal relationship only holds under Rayleigh scattering conditions, which rarely occur in real tissue. This paper presents a method for learning the elevational correlation length of US signals in arbitrary tissue from a set of example synthetic US scans using sparse Gaussian process regression. Experiments on synthetic and real imagery of animal tissue show that the data driven approach generalises well across transducers, yielding results of accuracy superior to a base-line speckle detection approach and comparable to the state of the art [1]. Additionally, the new approach uniquely provides a measure of uncertainty in the estimated correlation length.

Original languageEnglish
Title of host publicationProceedings - 2009 IEEE International Symposium on Biomedical Imaging
Subtitle of host publicationFrom Nano to Macro, ISBI 2009
PublisherIEEE Computer Society
Pages995-998
Number of pages4
ISBN (Print)9781424439324
DOIs
Publication statusPublished - 2009
Externally publishedYes
Event6th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, ISBI 2009 - Boston, MA, United States
Duration: 28 Jun 2009 → 1 Jul 2009

Publication series

NameProceedings - 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro, ISBI 2009

Conference

Conference6th IEEE International Symposium on Biomedical Imaging: From Nano to Macro, ISBI 2009
Country/TerritoryUnited States
CityBoston, MA
Period28/06/09 → 1/07/09