TY - GEN
T1 - Non-contact measurement of circular surfaces via photometric stereo in polar coordinates
AU - Radler, Bernhard
AU - Harker, Matthew
AU - O'Leary, Paul
AU - Lucyshyn, Thomas
N1 - Publisher Copyright:
© 2016 IEEE.
PY - 2016/7/22
Y1 - 2016/7/22
N2 - The measurement of the warpage of injection molded parts in polymer processing is a central task in the quality control of production processes. Complex high-end products are very challenging in terms of quality inspection. Therefore, a lot of effort is made in order to measure the shape using contact measuring systems, despite the reduced flexibility and increased duration of the measurement process. This paper presents a new approach of non-contact measurement using Photometric Stereo. Photometric Stereo brings all the benefits of an optical, contact-free measurement system along with fast analysis of the data. The principle of operation consists of two parts: the optical measurement of the gradient field by an industrial gigE-camera and the surface reconstruction by a global least squares approach. The minimum of three light-sources was extended to a set-up with four LEDs to gain more precision by additional data. A new surface reconstruction method, based on surface reconstruction from polar gradient fields was developed and tested. This is the first approach of using gradient fields in polar coordinates to direct surface reconstruction from gradients for industrial Photometric Stereo. For the evaluation of the proposed method a fully functional test set-up was built. The resulting measurement set-up is robust enough to be used directly on the shop floor for quality control.
AB - The measurement of the warpage of injection molded parts in polymer processing is a central task in the quality control of production processes. Complex high-end products are very challenging in terms of quality inspection. Therefore, a lot of effort is made in order to measure the shape using contact measuring systems, despite the reduced flexibility and increased duration of the measurement process. This paper presents a new approach of non-contact measurement using Photometric Stereo. Photometric Stereo brings all the benefits of an optical, contact-free measurement system along with fast analysis of the data. The principle of operation consists of two parts: the optical measurement of the gradient field by an industrial gigE-camera and the surface reconstruction by a global least squares approach. The minimum of three light-sources was extended to a set-up with four LEDs to gain more precision by additional data. A new surface reconstruction method, based on surface reconstruction from polar gradient fields was developed and tested. This is the first approach of using gradient fields in polar coordinates to direct surface reconstruction from gradients for industrial Photometric Stereo. For the evaluation of the proposed method a fully functional test set-up was built. The resulting measurement set-up is robust enough to be used directly on the shop floor for quality control.
KW - Non-Contact Measurement
KW - Photometric Stereo
KW - Polar Gradient Fields
KW - Surface Reconstruction
UR - https://www.scopus.com/pages/publications/84980347855
U2 - 10.1109/I2MTC.2016.7520467
DO - 10.1109/I2MTC.2016.7520467
M3 - Contribution to conference proceedings
AN - SCOPUS:84980347855
T3 - Conference Record - IEEE Instrumentation and Measurement Technology Conference
BT - I2MTC 2016 - 2016 IEEE International Instrumentation and Measurement Technology Conference
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2016 IEEE International Instrumentation and Measurement Technology Conference, I2MTC 2016
Y2 - 23 May 2016 through 26 May 2016
ER -