Skip to main navigation Skip to search Skip to main content

Part 1: Correlation between PPMV and mass leakage rate of gasketing products

  • Polytechnique Montréal

Research output: Contribution to journal › Journal Article › peer-review

Abstract

A study named as Projects 96-11G and 97-11G was performed to investigate the correlation between PPMV (Part Per Million by Volume) of methane gas emissions of pressurized equipment and the corresponding measured mass leakage rates and to verify existing empirical formulas proposed by the Environmental Protection Agency (EPA). Methane gas was chosen as directed by the PVRC subcommittee on Gasket Testing and Elevated Temperature Joint Behavior. It was found that the standard bagging blow through method is an accurate method for PPMV emission measurements. Gas chromatography accurately measured PPMV concentration above 25 PPMV.

Original languageEnglish
Pages (from-to)1-11
Number of pages11
JournalWelding Research Council Bulletin
Issue number484
Publication statusPublished - Aug 2003
Externally publishedYes

ASJC Scopus subject areas

  • Mechanical Engineering

Fingerprint

Dive into the research topics of 'Part 1: Correlation between PPMV and mass leakage rate of gasketing products'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.

Cite this