TY - GEN
T1 - Phase angles as predictors of network dynamic security limits and further implications
AU - Kaci, A.
AU - Kamwa, I.
AU - Dessaint, L. A.
AU - Guillon, S.
N1 - Publisher Copyright:
© 2014 IEEE.
PY - 2014/10/29
Y1 - 2014/10/29
N2 - In the United States, the number of Phasor Measurement Units (PMU) will increase from 166 networked devices in 2010 to 1043 in 2014. According to the Department of Energy, they are being installed in order to 'evaluate and visualize reliability margin (which describes how close the system is to the edge of its stability boundary).' However, there is still a lot of debate in academia and industry around the usefulness of phase angles as unambiguous predictors of dynamic stability. In this paper, using 4-year of actual data from Hydro-Québec EMS, it is shown that phase angles enable satisfactory predictions of power transfer and dynamic security margins across critical interface using random forest models, with both explanation level and R-squares accuracy exceeding 99%. A generalized linear model (GLM) is next implemented to predict phase angles from day-ahead to hour-ahead time frames, using historical phase angles values and load forecast. Combining GLM based angles forecast with random forest mapping of phase angles to power transfers result in a new data-driven approach for dynamic security monitoring.
AB - In the United States, the number of Phasor Measurement Units (PMU) will increase from 166 networked devices in 2010 to 1043 in 2014. According to the Department of Energy, they are being installed in order to 'evaluate and visualize reliability margin (which describes how close the system is to the edge of its stability boundary).' However, there is still a lot of debate in academia and industry around the usefulness of phase angles as unambiguous predictors of dynamic stability. In this paper, using 4-year of actual data from Hydro-Québec EMS, it is shown that phase angles enable satisfactory predictions of power transfer and dynamic security margins across critical interface using random forest models, with both explanation level and R-squares accuracy exceeding 99%. A generalized linear model (GLM) is next implemented to predict phase angles from day-ahead to hour-ahead time frames, using historical phase angles values and load forecast. Combining GLM based angles forecast with random forest mapping of phase angles to power transfers result in a new data-driven approach for dynamic security monitoring.
KW - Data mining
KW - Dynamic Security Assessment (DSA)
KW - Dynamic Security Monitoring
KW - Phasor measurement unit (PMU)
KW - Random Forest (RF)
KW - Synchrophasor
KW - System reliability
KW - Wide-Area Situational Awareness (WASA)
UR - https://www.scopus.com/pages/publications/84930988902
U2 - 10.1109/PESGM.2014.6939281
DO - 10.1109/PESGM.2014.6939281
M3 - Contribution to conference proceedings
AN - SCOPUS:84930988902
T3 - IEEE Power and Energy Society General Meeting
BT - 2014 IEEE PES General Meeting / Conference and Exposition
PB - IEEE Computer Society
T2 - 2014 IEEE Power and Energy Society General Meeting
Y2 - 27 July 2014 through 31 July 2014
ER -