Robustness and reproducibility of a glenoid-centered scapular coordinate system derived from low-dose stereoradiography analysis

  • Xavier Ohl
  • , Pierre Yves Lagacé
  • , Fabien Billuart
  • , Olivier Gagey
  • , Wafa Skalli
  • , Nicola Hagemeister
  • Ecole Nationale Supérieure d'Arts et Métiers
  • CHU de Reims
  • Centre Hospitalier de L'Universite de Montreal
  • Assistance publique – Hôpitaux de Paris

Research output: Contribution to journal › Journal Article › peer-review

14 Citations (Scopus)

Abstract

A robust and reproducible scapular coordinate system is necessary to study scapulothoracic kinematics. The coordinate system recommended by the ISB (International Society of Biomechanics) is difficult to apply in studies using medical imaging, which mostly use a glenoid-centered coordinate system. The aim of this study was to assess the robustness of a glenoid-centered coordinate system compared with the ISB coordinate system, and to study the reproducibility of this coordinate system measure during abduction. A Monte-Carlo analysis was performed to test the robustness of the two coordinate systems. This method enabled the variability of the orientation of the coordinate system to be assessed in a laboratory setting. A reproducibility study of the glenoid-centered coordinate system in the thorax reference frame was performed during abduction in the scapular plane using a low-dose stereoradiography system. We showed that the glenoid-centered coordinate system was slightly more robust than the ISB-recommended coordinate system. Most reproducible rotation was upward/downward rotation (x axis) and most reproducible translation was along the Y axis (superior-inferior translation). In conclusion, the glenoid-centered coordinate system can be used with confidence for scapular kinematics analysis. The uncertainty of the measures derived from our technique is acceptable compared with that reported in the literature. Functional quantitative analysis of the scapulothoracic joint is possible with this method.

Original languageEnglish
Pages (from-to)56-61
Number of pages6
JournalJournal of Applied Biomechanics
Volume31
Issue number1
DOIs
Publication statusPublished - 1 Feb 2015
Externally publishedYes

Keywords

  • Coordinate system
  • Reproducibility
  • Shoulder kinematics
  • Stereoradiography

ASJC Scopus subject areas

  • General Medicine

Fingerprint

Dive into the research topics of 'Robustness and reproducibility of a glenoid-centered scapular coordinate system derived from low-dose stereoradiography analysis'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.

Cite this