Abstract
Testing high-strength concrete (HSC) for compressive strength puts into doubt a certain number of concrete testing practices. First, most concrete testing laboratories are equipped with loading capacity machines inadequate for testing 150 × 300-mm (6 × 12-in) specimens, thus limiting HSC specimens to 100 × 200 mm (4 × 8 in) in size. As most designers rely on compressive strengths derived from large specimens, they must be given relations between the different values obtained when smaller specimens are used. Comparative testing reveals that HSC compressive strength values are greater by 5 percent when measured on 100 × 200-mm specimens is as small as, or smaller than, that for 150 × 300-mm specimens.