Skip to main navigation Skip to search Skip to main content

Testing high-strength concrete compressive strength

  • Université de Sherbrooke

Research output: Contribution to journal › Journal Article › peer-review

62 Citations (Scopus)

Abstract

Testing high-strength concrete (HSC) for compressive strength puts into doubt a certain number of concrete testing practices. First, most concrete testing laboratories are equipped with loading capacity machines inadequate for testing 150 × 300-mm (6 × 12-in) specimens, thus limiting HSC specimens to 100 × 200 mm (4 × 8 in) in size. As most designers rely on compressive strengths derived from large specimens, they must be given relations between the different values obtained when smaller specimens are used. Comparative testing reveals that HSC compressive strength values are greater by 5 percent when measured on 100 × 200-mm specimens is as small as, or smaller than, that for 150 × 300-mm specimens.

Original languageEnglish
Pages (from-to)303-308
Number of pages6
JournalACI Materials Journal
Volume90
Issue number4
Publication statusPublished - Jul 1993
Externally publishedYes

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Building and Construction
  • General Materials Science

Fingerprint

Dive into the research topics of 'Testing high-strength concrete compressive strength'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.

Cite this