Abstract
Two nozzle designs, involving the same low aspect ratio, high turning angle vanes, and differing in outer wall contour, were tested over a range of exit Mach numbers up to supersonic values. The experiments were conducted on a large-scale, full annular configuration with andwithout a representative rotor downstream. Nozzle performance was foundto be significantly affected by rotor operation, the influence depending on the detailed characteristics of the nozzle flow field, as well as on the design and operation of the rotor itself. It is suggested that performance evaluation of low aspect ratio nozzles of high turning anglemay require appropriate testing with a rotor.
| Original language | English |
|---|---|
| Pages (from-to) | 269-274 |
| Number of pages | 6 |
| Journal | Journal of Turbomachinery |
| Volume | 108 |
| Issue number | 2 |
| DOIs | |
| Publication status | Published - Oct 1986 |
| Externally published | Yes |