Skip to main navigation Skip to search Skip to main content

The effect of a downstream rotor on the measured performance of a transonic turbine nozzle

  • National Research Council of Canada
  • United Technologies Corporation

Research output: Contribution to journal › Journal Article › peer-review

10 Citations (Scopus)

Abstract

Two nozzle designs, involving the same low aspect ratio, high turning angle vanes, and differing in outer wall contour, were tested over a range of exit Mach numbers up to supersonic values. The experiments were conducted on a large-scale, full annular configuration with andwithout a representative rotor downstream. Nozzle performance was foundto be significantly affected by rotor operation, the influence depending on the detailed characteristics of the nozzle flow field, as well as on the design and operation of the rotor itself. It is suggested that performance evaluation of low aspect ratio nozzles of high turning anglemay require appropriate testing with a rotor.

Original languageEnglish
Pages (from-to)269-274
Number of pages6
JournalJournal of Turbomachinery
Volume108
Issue number2
DOIs
Publication statusPublished - Oct 1986
Externally publishedYes

ASJC Scopus subject areas

  • Mechanical Engineering

Fingerprint

Dive into the research topics of 'The effect of a downstream rotor on the measured performance of a transonic turbine nozzle'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.

Cite this