TY - GEN
T1 - Variation of strain rate sensitivity index of a superplastic aluminum alloy in different testing methods
AU - Majidi, Omid
AU - Jahazi, Mohammad
AU - Bombardier, Nicolas
AU - Samuel, Ehab
N1 - Publisher Copyright:
© 2017 Author(s).
PY - 2017/10/16
Y1 - 2017/10/16
N2 - The strain rate sensitivity index, m-value, is being applied as a common tool to evaluate the impact of the strain rate on the viscoplastic behaviour of materials. The m-value, as a constant number, has been frequently taken into consideration for modeling material behaviour in the numerical simulation of superplastic forming processes. However, the impact of the testing variables on the measured m-values has not been investigated comprehensively. In this study, the m-value for a superplastic grade of an aluminum alloy (i.e., AA5083) has been investigated. The conditions and the parameters that influence the strain rate sensitivity for the material are compared with three different testing methods, i.e., monotonic uniaxial tension test, strain rate jump test and stress relaxation test. All tests were conducted at elevated temperature (470°C) and at strain rates up to 0.1 s-1. The results show that the m-value is not constant and is highly dependent on the applied strain rate, strain level and testing method.
AB - The strain rate sensitivity index, m-value, is being applied as a common tool to evaluate the impact of the strain rate on the viscoplastic behaviour of materials. The m-value, as a constant number, has been frequently taken into consideration for modeling material behaviour in the numerical simulation of superplastic forming processes. However, the impact of the testing variables on the measured m-values has not been investigated comprehensively. In this study, the m-value for a superplastic grade of an aluminum alloy (i.e., AA5083) has been investigated. The conditions and the parameters that influence the strain rate sensitivity for the material are compared with three different testing methods, i.e., monotonic uniaxial tension test, strain rate jump test and stress relaxation test. All tests were conducted at elevated temperature (470°C) and at strain rates up to 0.1 s-1. The results show that the m-value is not constant and is highly dependent on the applied strain rate, strain level and testing method.
UR - https://www.scopus.com/pages/publications/85037684905
U2 - 10.1063/1.5007979
DO - 10.1063/1.5007979
M3 - Contribution to conference proceedings
AN - SCOPUS:85037684905
T3 - AIP Conference Proceedings
BT - Proceedings of the 20th International ESAFORM Conference on Material Forming, ESAFORM 2017
A2 - Brabazon, Dermot
A2 - Ul Ahad, Inam
A2 - Naher, Sumsun
PB - American Institute of Physics Inc.
T2 - 20th International ESAFORM Conference on Material Forming, ESAFORM 2017
Y2 - 26 April 2017 through 28 April 2017
ER -