Modélisation, conception et simulation des performances d'un collecteur solaire aéraulique à tubes sous vide en milieu nordique

Translated title of the thesis: Modeling, design and simulation of the performances of a solar air collector using vaccum tubes for cold climate
  • Pierre-Luc Paradis

Student thesis: Master's thesisMaster in Engineering: Mechanical Engineering

Abstract

The global energy consumption is still increasing year after year even if different initiatives are set up to decrease fossil fuel dependency. In Canada 80% of the energy is used for space heating and domestic hot water heating in residential sector. This heat could be provided by solar thermal technologies despite few difficulties originating from the cold climate. The aim of this project is to design a solar evacuated tube thermal collector using air as the working fluid. Firstly, needs and specifications of the product are established in a clear way. Then, three concepts of collector are presented. The first one relies on the standard evacuated tube. The second one uses a new technology of tubes; both sides are open. The third one uses heat pipe to extract the heat from the tubes. Based on the needs and specification as criteria, the concept involving tubes with both sides open has been selected as the best idea. In order to simulate the performances of the collector, a model of the heat exchanges in an evacuated tube was developed in 4 steps. The first step is a model in steady state intended to calculate the stagnation temperature of the tube for a fixed solar radiation, outside temperature and wind speed. As a second step, the model is generalised to transient condition in order to validate it with an experimental setup. A root mean square error of 2% is then calculated. The two remainder steps are intended to calculate the temperature of airflow leaving the tube. In the same way, a first model in steady state is developed and then generalised to the transient mode. Then, the validation with an experimental setup gave a difference of 0.2% for the root mean square error. Finally, a preindustrial prototype intended to work in open loop for preheating of fresh air is presented. During the project, explosion of the both sides open evacuated tube in overheating condition blocked the construction of a real prototype for the test. Different path for further work are also identified. One of these is in relation with CFD simulation of the uniformity of the airflow inside of the collector. Another one is the analysis of the design with a design of experiment plan.
Date14 Jul 2014
Original languageFrench
Awarding Institution
  • École de technologie supérieure
SupervisorDaniel Rousse (Supervisor) & Stéphane Hallé (Co-supervisor)

Cite this

'