Passer à la navigation principale Passer à la recherche Passer au contenu principal

3-D reconstruction of the coronary artery tree from multiple views of a rotational X-ray angiography

  • Rui Liao
  • , Duong Luc
  • , Yiyong Sun
  • , Klaus Kirchberg
  • Siemens

Résultats de recherche: Contribution à un journal › Article publié dans une revue, révisé par les pairs › Revue par des pairs

53 Citations (Scopus)

Résumé

To present an efficient and robust method for 3-D reconstruction of the coronary artery tree from multiple ECG-gated views of an X-ray angiography. 2-D coronary artery centerlines are extracted automatically from X-ray projection images using an enhanced multi-scale analysis. For the difficult data with low vessel contrast, a semi-automatic tool based on fast marching method is implemented to allow manual correction of automatically-extracted 2-D centerlines. First, we formulate the 3-D symbolic reconstruction of coronary arteries from multiple views as an energy minimization problem incorporating a soft epipolar line constraint and a smoothness term evaluated in 3-D. The proposed formulation results in the robustness of the reconstruction to the imperfectness in 2-D centerline extraction, as well as the reconstructed coronary artery tree being inherently smooth in 3-D. We further propose to solve the energy minimization problem using α-expansion moves of Graph Cuts, a powerful optimization technique that yields a local minimum in a strong sense at a relatively low computational complexity. We show experimental results on a synthetic coronary phantom, a porcine data set and 11 patient data sets. For the coronary phantom, results obtained using different number of views are presented. 3-D reconstruction error evaluated by the mean plus one standard deviation is below one millimeter when 4 or more views are used. For real data, reconstruction using 4 to 5 views and 256 depth labels averaged around 12 s on a computer with 2.13 GHz Intel Pentium M and achieves a mean 2-D back-projection error of 1.18 mm (ranging from 0.84 to 1.71 mm) in 12 cases. The accuracy for multi-view reconstruction of the coronary artery tree as reported from the phantom and patient studies is promising, and the efficiency is significantly improved compared to other approaches reported in the literature, which range from a few to tens of minutes. Visually good and smooth reconstruction is demonstrated.

Langue originaleAnglais
Pages (de - à)733-749
Nombre de pages17
RevueInternational Journal of Cardiovascular Imaging
Volume26
Numéro de publication7
Les DOIs
ÉtatPublié - oct. 2010
Modification externeOui

Classification disciplinaire ASJC Scopus

  • Radiologie, médecine nucléaire et imagerie
  • Cardiologie et médecine cardiovasculaire

Empreinte digitale

Voici les principaux termes ou expressions associés à « 3-D reconstruction of the coronary artery tree from multiple views of a rotational X-ray angiography ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.

Citer cette ressource