TY - GEN
T1 - A longitudinal statistical review of a dozen laboratory tests on an instantly custom-fitted earplug
AU - Voix, Jérémie
AU - Zeidan, Jean
PY - 2008
Y1 - 2008
N2 - An original custom earplug has been developed. It is instantly fitted to the ear canal by the injection of a two-part medical silicon filler into a very thin envelope which surrounds a core of generic shape and size. Over the years, the thickness of the envelope as well as the dimensions of the core have been optimized for attenuation and fit comfort. From late 2001 to mid-2007, three versions of the earplug were evaluated in independent third-party laboratories. Attenuation was measured on human subjects using the real-ear attenuation at threshold (REAT) method. The fit of the earplug was assessed through conditions of both "superviser-fit" (insertion by the laboratory technician) and "subject-fit" (self-insertion with only the guidance of the manufacturer's written instructions). Statistical analysis on the individual mean attenuation has been performed and reveals that the group average overall attenuation has been constantly rising (from 23.6 to 31.1 dB) while the standard-deviation of the group attenuation has been constantly decreasing. More surprisingly, the most recent group average attenuation is now marginally higher for subject-fit (at 31.6 dB) than for superviser-fit.
AB - An original custom earplug has been developed. It is instantly fitted to the ear canal by the injection of a two-part medical silicon filler into a very thin envelope which surrounds a core of generic shape and size. Over the years, the thickness of the envelope as well as the dimensions of the core have been optimized for attenuation and fit comfort. From late 2001 to mid-2007, three versions of the earplug were evaluated in independent third-party laboratories. Attenuation was measured on human subjects using the real-ear attenuation at threshold (REAT) method. The fit of the earplug was assessed through conditions of both "superviser-fit" (insertion by the laboratory technician) and "subject-fit" (self-insertion with only the guidance of the manufacturer's written instructions). Statistical analysis on the individual mean attenuation has been performed and reveals that the group average overall attenuation has been constantly rising (from 23.6 to 31.1 dB) while the standard-deviation of the group attenuation has been constantly decreasing. More surprisingly, the most recent group average attenuation is now marginally higher for subject-fit (at 31.6 dB) than for superviser-fit.
UR - https://www.scopus.com/pages/publications/84870035013
M3 - Contribution to conference proceedings
AN - SCOPUS:84870035013
SN - 9781605605401
T3 - Institute of Noise Control Engineering of the USA - 23rd National Conference on Noise Control Engineering, NOISE-CON 08 and Sound Quality Symposium, SQS 08
SP - 728
EP - 737
BT - Institute of Noise Control Engineering of the USA - 23rd National Conference on Noise Control Engineering, NOISE-CON 08 and Sound Quality Symposium, SQS 08
T2 - 23rd National Conference on Noise Control Engineering, NOISE-CON 2008 and 3rd Sound Quality Symposium, SQS 2008
Y2 - 28 July 2008 through 31 July 2008
ER -