Résumé
A mathematical model of a hot air anti-icing system and its implementation in the ice accretion simulation code CANICE are presented. The icing code is used to predict the surface temperature and the amount of runback water for given atmospheric conditions and heat flux distribution from an anti-icing device. The external boundary layer is modeled with an integral method. Velocity and temperature distribution in the water film are estimated using a polynomial approximation. Conduction in the airfoil skin is taken into account with a one-dimension model. Numerical results are compared with experimental and numerical results from NASA for three different icing conditions. The comparison shows that surface temperatures are very sensitive to the water droplet impingement limits. The integral method used here failed to predict correctly the heat transfer coefficients in the transition region of the boundary layer. When experimental heat transfer coefficients are used, the model gives satisfactory results.
| langue originale | Anglais |
|---|---|
| Pages (de - à) | 999-1006 |
| Nombre de pages | 8 |
| journal | Journal of Aircraft |
| Volume | 36 |
| Numéro de publication | 6 |
| Les DOIs | |
| état | Publié - 1999 |
| Modification externe | Oui |
Classification disciplinaire ASJC Scopus
- Ingénierie aérospatiale
Empreinte digitale
Voici les principaux termes ou expressions associés à « Anti-icing system simulation using CANICE ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.Citer cette ressource
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver