TY - GEN
T1 - Automatic Artifact Detection in Impedance Cardiogram Using Pulse Similarity Index
AU - Forouzanfar, Mohamad
AU - Baker, Fiona C.
AU - Colrain, Ian M.
AU - De Zambotti, Massimiliano
N1 - Publisher Copyright:
© 2019 IEEE.
PY - 2019/7
Y1 - 2019/7
N2 - Impedance cardiography (ICG) is a noninvasive technique for evaluation of cardiac hemodynamic parameters such as cardiac output and pre-ejection period. However, the sensitivity of the technique to motion artifact, electrode displacement, and cardiovascular pathologies can severely impact the accuracy of hemodynamic parameter estimates. In this paper, we proposed a new algorithm for the automatic detection and exclusion of corrupted ICG cardiac cycles by defining a pulse similarity index that quantifies the level of pulse corruption and its diversion from a typical-shaped pulse. The index considers different features (activity, structure, shape, and pattern) of the ICG cardiac cycles. The algorithm is compared on sleep data collected from 20 participants against expert identified corrupted cycles. The artifact rejection algorithm achieved a high accuracy of 96% in detection of expert-identified corrupted ICG cycles, including those with normal amplitude as well as out-of-range values, and was robust to different types and levels of artifact. The algorithm shows promise toward applications requiring accurate and reliable automatic measurement of cardiac hemodynamic parameters from prolonged data sets.
AB - Impedance cardiography (ICG) is a noninvasive technique for evaluation of cardiac hemodynamic parameters such as cardiac output and pre-ejection period. However, the sensitivity of the technique to motion artifact, electrode displacement, and cardiovascular pathologies can severely impact the accuracy of hemodynamic parameter estimates. In this paper, we proposed a new algorithm for the automatic detection and exclusion of corrupted ICG cardiac cycles by defining a pulse similarity index that quantifies the level of pulse corruption and its diversion from a typical-shaped pulse. The index considers different features (activity, structure, shape, and pattern) of the ICG cardiac cycles. The algorithm is compared on sleep data collected from 20 participants against expert identified corrupted cycles. The artifact rejection algorithm achieved a high accuracy of 96% in detection of expert-identified corrupted ICG cycles, including those with normal amplitude as well as out-of-range values, and was robust to different types and levels of artifact. The algorithm shows promise toward applications requiring accurate and reliable automatic measurement of cardiac hemodynamic parameters from prolonged data sets.
UR - https://www.scopus.com/pages/publications/85074406390
U2 - 10.1109/EMBC.2019.8856542
DO - 10.1109/EMBC.2019.8856542
M3 - Contribution to conference proceedings
C2 - 31946435
AN - SCOPUS:85074406390
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 2629
EP - 2632
BT - 2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2019
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2019
Y2 - 23 July 2019 through 27 July 2019
ER -