Biomechanical testing of a hybrid locking plate fixation of equine sesamoid osteotomies

  • E. Almeida da Silveira
  • , A. Levasseur
  • , M. Lacourt
  • , Y. Elce
  • , Y. Petit
  • University of Montreal
  • École de technologie supérieure

Résultats de recherche: Contribution à un journal › Article publié dans une revue, révisé par les pairs › Revue par des pairs

2 Citations (Scopus)

Résumé

Objective: To compare the biomechanical properties of a hybrid locking compression plate (LCP) construct with the compression screw technique as a treatment for transverse mid-body proximal sesamoid bone fractures. Methods: Ten paired forelimbs from abattoir horses were used. The medial proximal sesamoid bone of each limb was osteotomized transversely and randomly assigned, to either repair with a two-hole 3.5 mm LCP or a 4.5 mm cortical screw placed in lag fashion. Each limb was tested biomechanically by axial loading in single cycle until failure. The point of failure was evaluated from the loaddisplacement curves. Then a gross evaluation and radiographs were performed to identify the mode of failure. Results: The loads to failure of limbs repaired with the hybrid LCP construct (4968 N ± 2167) and the limbs repaired with the screw technique (3009 N ± 1091) were significantly different (p <0.01). The most common mode of failure was through a comminuted fracture of the apical fragment of the proximal sesamoid bone. Clinical significance: The LCP technique has potential to achieve a better fracture stability and healing when applied to mid-body fractures of the proximal sesamoid bone. Further testing, particularly fatigue resistance is required to corroborate its potential as a treatment option for mid-body fractures of the proximal sesamoid bone.

langue originaleAnglais
Pages (de - à)107-112
Nombre de pages6
journalVeterinary and Comparative Orthopaedics and Traumatology
Volume27
Numéro de publication2
Les DOIs
étatPublié - 2014

Empreinte digitale

Voici les principaux termes ou expressions associés à « Biomechanical testing of a hybrid locking plate fixation of equine sesamoid osteotomies ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.

Citer cette ressource