Passer à la navigation principale Passer à la recherche Passer au contenu principal

CFD simulations to improve air distribution inside cold climate broiler houses involving heat exchangers

  • École de technologie supérieure
  • Energy Solutions Air

Résultats de recherche: Contribution à un journal › Article publié dans une revue, révisé par les pairs › Revue par des pairs

16 Citations (Scopus)

Résumé

Propane heating is both a financial and an environmental burden for broiler houses located in cold climate regions. Heat recovery can reduce propane consumption significantly, by preheating fresh air inflow with stalled air outflow. While there have been many studies on the improvement of broiler houses direct ventilation, little attention has been given to the integration of heat exchangers. In this study, an existing broiler house (800 m2) equipped with two air-to-air ductless heat exchangers (0.38 m3s-1 each) was simulated. Computational fluid dynamics (CFD) software OpenFOAM was used to create a 3D steady-state buoyant simulation with RNG k-ε turbulence model. The CFD model was validated with experimental data from Nielsen (1976). In the reference configuration, the two heat exchangers were aligned in parallel, positioned against the northern wall. Three alternative heat exchangers configurations were simulated and analysed in their ability to provide adequate, uniform velocity, temperature and air age at bird height. No configuration was found to avoid excessive air velocities entirely. One configuration (C1) reduced the air age standard deviation from 477 to 179 s. It also increased the surface with adequate air quality from 55% (C0, reference case) to 72% of the floor area. Despite using the same heating power, temperature differences of up to 2 °C were observed in the mean air temperature of broiler zones of different configurations. These results confirm that ventilation performance can be improved by a careful analysis of heat exchangers position and its effects on airflow patterns.

langue originaleAnglais
Pages (de - à)105-118
Nombre de pages14
journalBiosystems Engineering
Volume198
Les DOIs
étatPublié - oct. 2020

Empreinte digitale

Voici les principaux termes ou expressions associés à « CFD simulations to improve air distribution inside cold climate broiler houses involving heat exchangers ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.

Citer cette ressource