Résumé
Complement to standard E2611-09 of the American Society for Testing and Materials [Standard Test Method for Measurement of Normal Incidence Sound Transmission of Acoustical Materials Based on the Transfer Matrix Method (American Society for Testing and Materials, New York, 2009)] is proposed in order to measure normal incidence sound transmission loss of materials in a modified impedance tube using a three-microphone two-load or one-load method. The modified tube is a standard two-microphone impedance tube, where a third microphone is mounted on a movable hard termination. This method is conceptually identical to the four-microphone two-load or one-load method described in the standard; however, it requires fewer transfer functions and one microphone less. The method is validated on (1) symmetrical homogeneous and (2) non-symmetrical non-homogeneous specimens.
| Langue originale | Anglais |
|---|---|
| Pages (de - à) | EL216-EL222 |
| Revue | Journal of the Acoustical Society of America |
| Volume | 131 |
| Numéro de publication | 3 |
| Les DOIs | |
| État | Publié - mars 2012 |
| Modification externe | Oui |
Classification disciplinaire ASJC Scopus
- Arts et sciences humaines (divers)
- Acoustique et ultrasons
Empreinte digitale
Voici les principaux termes ou expressions associés à « Complement to standard method for measuring normal incidence sound transmission loss with three microphones ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.Citer cette ressource