Passer à la navigation principale Passer à la recherche Passer au contenu principal

Evaluation of subsurface heat capacity through oscillatory thermal response tests†

  • Institut national de la recherche scientifique

Résultats de recherche: Contribution à un journal › Article publié dans une revue, révisé par les pairs › Revue par des pairs

10 Citations (Scopus)

Résumé

Two methods are currently available to estimate in a relatively short time span the sub-surface heat capacity: (1) laboratory analysis of rock/soil samples; (2) measure the heat diffusion with temperature sensors in an observation well. Since the first may not be representative of in-situ conditions, and the second imply economical and logistical issues, a third option might be possible by means of so-called oscillatory thermal response tests (OTRT). The aim of the study was to evaluate the effectiveness of an OTRT as a tool to infer the subsurface heat capacity without the need of an observation well. To achieve this goal, an OTRT was carried out in a borehole heat exchanger (BHE). The total duration of injection was 6 days, with oscillation period of 12 h and amplitude of 10 W m−1 . The results of the proposed methodology were compared 3-D numerical simulations and to a TRT with a constant heat injection rate with temperature response monitored from a nearby observation well. Results show that the OTRT succeeded to infer the expected subsurface heat capacity, but uncertainty is about 15% and the radial depth of penetration is only 12 cm. The parameters having most impact on the results are the subsurface thermal conductivity and the borehole thermal resistance. The OTRT performed and analyzed in this study also allowed to evaluate the thermal conductivity with similar accuracy compared to conventional TRTs (3%). On the other hand, it returned borehole thermal resistance with high uncertainty (15%), in particular due to the duration of the test. The final range of heat capacity is wide, highlighting challenges to currently use OTRT in the scope of ground-coupled heat pump system design. OTRT appears a promising tool to evaluate the heat capacity, but more field testing and mathematical interpretation of the sinusoidal response is needed to better isolate the subsurface from the BHE contribution and reduce the uncertainty.

langue originaleAnglais
Numéro d'article5791
journalEnergies
Volume14
Numéro de publication18
Les DOIs
étatPublié - sept. 2021

SDG des Nations Unies

Ce résultat contribue à ou aux Objectifs de développement durable suivants

  1. SDG 7 – Energie propre et d'un coût abordable
    SDG 7 – Energie propre et d'un coût abordable

Classification disciplinaire ASJC Scopus

  • Energies renouvelables, développement durable et environnement
  • Technologie des carburants
  • Ingénierie énergétique et technologie de l'énergie
  • Energie (divers)
  • Contrôle et optimisation
  • Ingénierie électrique et électronique

Empreinte digitale

Voici les principaux termes ou expressions associés à « Evaluation of subsurface heat capacity through oscillatory thermal response tests† ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.