Passer à la navigation principale Passer à la recherche Passer au contenu principal

Femoral stem incorporating a diamond cubic lattice structure: Design, manufacture and testing

  • École de technologie supérieure

Résultats de recherche: Contribution à un journal › Article publié dans une revue, révisé par les pairs › Revue par des pairs

119 Citations (Scopus)

Résumé

Background The current total hip prostheses with dense femoral stems are considerably stiffer than the host bones, which leads to such long-term complications as aseptic loosening, and eventually, the need for a revision. Consequently, the lifetime of the implantation does not match the lifetime expectation of young patients. Method A femoral stem design featuring a porous structure is proposed to lower its stiffness and allow bone tissue ingrowth. The porous structure is based on a diamond cubic lattice in which the pore size and the strut thickness are selected to meet the biomechanical requirements of the strength and the bone ingrowth. A porous stem and its fully dense counterpart are produced by laser powder-bed fusion using Ti-6Al-4V alloy. To evaluate the stiffness reduction, static testing based on the ISO standard 7206-4 is performed. The experimental results recorded by digital image correlation are analyzed and compared to the numerical model. Results & conclusions The numerical and experimental force-displacement characteristics of the porous stem show a 31% lower stiffness as compared to that of its dense counterpart. Moreover, the correlation analysis of the total displacement and equivalent strain fields allows the preliminary validation of the numerical model of the porous stem. Finally, the analysis of the surface-to-volume and the strength-to-stiffness ratios of diamond lattice structures allow the assessment of their potential as biomimetic constructs for load-bearing orthopaedic implants.

Langue originaleAnglais
Pages (de - à)58-72
Nombre de pages15
RevueJournal of the Mechanical Behavior of Biomedical Materials
Volume77
Les DOIs
ÉtatPublié - janv. 2018

Classification disciplinaire ASJC Scopus

  • Biomatériaux
  • Ingénierie biomédicale
  • Mécanique des matériaux

Empreinte digitale

Voici les principaux termes ou expressions associés à « Femoral stem incorporating a diamond cubic lattice structure: Design, manufacture and testing ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.