TY - GEN
T1 - High temperature aged leakage relaxation screening tests on confined flexible graphite gaskets
AU - Bouzid, Abdel Hakim
AU - Das, Shubhra Kanti
N1 - Publisher Copyright:
Copyright © 2021 by ASME.
PY - 2021
Y1 - 2021
N2 - Flexible graphite-based gaskets are used extensively in high-temperature applications as a replacement of asbestos based gaskets. The effect of aging and temperature exposure of flexible graphite sheet gaskets was the subject of a previous work [1,2], however, the effect when flexible graphite is in a confined gasket configuration is not known. This study outlines the performance evaluation of the elevated temperature behavior of flexible graphite-based gaskets under a confined configuration and exposed over a long period employing HALR (High temperature Aged Leakage Relaxation) fixture. This ARLA-like fixture can retain the mechanical feature of the ATRS/HATR while allowing the cold leakage rate and weight loss measurement. Four different confined gasket configurations, namely corrugated metal, spiral wound, kammprofile and double jacketed, are evaluated within a temperature range of (427 to 649 °C) 800 to 1200 °F and exposure time of 2500 hours. Graphite weight loss, gasket thickness change, leakage and tightness parameter, creep and relaxation measurements were taken at regular intervals for each gasket style. To better understand the aging process, these critical mechanical and leakage properties are scrutinized; the degradation process related to mainly graphite oxidation is further discussed, and a conclusion is drawn.
AB - Flexible graphite-based gaskets are used extensively in high-temperature applications as a replacement of asbestos based gaskets. The effect of aging and temperature exposure of flexible graphite sheet gaskets was the subject of a previous work [1,2], however, the effect when flexible graphite is in a confined gasket configuration is not known. This study outlines the performance evaluation of the elevated temperature behavior of flexible graphite-based gaskets under a confined configuration and exposed over a long period employing HALR (High temperature Aged Leakage Relaxation) fixture. This ARLA-like fixture can retain the mechanical feature of the ATRS/HATR while allowing the cold leakage rate and weight loss measurement. Four different confined gasket configurations, namely corrugated metal, spiral wound, kammprofile and double jacketed, are evaluated within a temperature range of (427 to 649 °C) 800 to 1200 °F and exposure time of 2500 hours. Graphite weight loss, gasket thickness change, leakage and tightness parameter, creep and relaxation measurements were taken at regular intervals for each gasket style. To better understand the aging process, these critical mechanical and leakage properties are scrutinized; the degradation process related to mainly graphite oxidation is further discussed, and a conclusion is drawn.
KW - Aging
KW - Confined flexible graphite
KW - Degradation and oxidation
KW - High temperature Aged Leakage Relaxation (HALR)
KW - Temperature exposure
UR - https://www.scopus.com/pages/publications/85117911631
U2 - 10.1115/PVP2021-61730
DO - 10.1115/PVP2021-61730
M3 - Contribution to conference proceedings
AN - SCOPUS:85117911631
T3 - American Society of Mechanical Engineers, Pressure Vessels and Piping Division (Publication) PVP
BT - Computer Technology and Bolted Joints; Design and Analysis
PB - American Society of Mechanical Engineers (ASME)
T2 - ASME 2021 Pressure Vessels and Piping Conference, PVP 2021
Y2 - 13 July 2021 through 15 July 2021
ER -