TY - JOUR
T1 - Open-Phase Fault-Tolerant Operation of the Three-Phase Dual Active Bridge Converter
AU - Berger, Maxime
AU - Kocar, Ilhan
AU - Fortin-Blanchette, Handy
AU - Lavertu, Carl
N1 - Publisher Copyright:
© 1986-2012 IEEE.
PY - 2020/4
Y1 - 2020/4
N2 - The three-phase dual active bridge (3p-DAB) converter is widely considered in dc-grid applications. Because of the higher number of switches in the 3p-DAB, it can be argued that the reliability of the 3p-DAB is reduced when compared to other isolated-bidirectional dc-dc converter topologies. The previous work has shown that the 3p-DAB can be operated in a frozen leg fault-tolerant mode, i.e., with the two transistors of the same phase being opened by their gate driver internal protections. Because the free-wheeling diodes are left self-commutated, the analytical characterization of the converter for all voltage and loading conditions is not trivial. In this article, it is proposed to open the faulty phase such as it eliminates the interaction with the faulty-phase free-wheeling diodes. This allows the converter to fall in a characterizable operating mode for all voltage and loading conditions. The results further show that the open-phase operation provides advantages over the frozen leg operation in terms of current stress and power transfer capability. Experimental results on a small-scale closed-loop gallium nitride-based prototype as well as time-domain simulation results are provided to support the theoretical analyses.
AB - The three-phase dual active bridge (3p-DAB) converter is widely considered in dc-grid applications. Because of the higher number of switches in the 3p-DAB, it can be argued that the reliability of the 3p-DAB is reduced when compared to other isolated-bidirectional dc-dc converter topologies. The previous work has shown that the 3p-DAB can be operated in a frozen leg fault-tolerant mode, i.e., with the two transistors of the same phase being opened by their gate driver internal protections. Because the free-wheeling diodes are left self-commutated, the analytical characterization of the converter for all voltage and loading conditions is not trivial. In this article, it is proposed to open the faulty phase such as it eliminates the interaction with the faulty-phase free-wheeling diodes. This allows the converter to fall in a characterizable operating mode for all voltage and loading conditions. The results further show that the open-phase operation provides advantages over the frozen leg operation in terms of current stress and power transfer capability. Experimental results on a small-scale closed-loop gallium nitride-based prototype as well as time-domain simulation results are provided to support the theoretical analyses.
KW - DC-DC power converters
KW - fault tolerance
KW - systems modeling
UR - https://www.scopus.com/pages/publications/85078358285
U2 - 10.1109/TPEL.2019.2933487
DO - 10.1109/TPEL.2019.2933487
M3 - Journal Article
AN - SCOPUS:85078358285
SN - 0885-8993
VL - 35
SP - 3651
EP - 3662
JO - IEEE Transactions on Power Electronics
JF - IEEE Transactions on Power Electronics
IS - 4
M1 - 8789518
ER -