TY - GEN
T1 - Optimized based algorithm first order sliding mode control for grid-connected packed e-cell (PEC) inverter
AU - Babaie, Mohammad
AU - Sharifzadeh, Mohammad
AU - Mehrasa, Majid
AU - Al-Haddad, Kamal
N1 - Publisher Copyright:
© 2019 IEEE.
PY - 2019/9
Y1 - 2019/9
N2 - In this paper, First Order Sliding Mode Control (FOSMC) has been optimally designed for single-phase grid-connected Packed E-Cell (PEC) inverter. PEC is a recent introduced advanced compact inverter topology generates multilevel voltage while capacitors are balanced using the redundant switching states. Therefore, the capacitor voltage balancing is no longer required to be assumed in the grid-connected controller. According to the proposed FOSMC, the sign function is replaced by saturation function to mitigate the chattering phenomenon and improve the controller performance. Afterwards, FOSMC weighting factors are optimized by Artificial Bee Colony (ABC) algorithm to compensate the saturation function error. The proposed OFOSMC has been evaluated by simulation and experimental analyses under both steady and variable conditions to investigate its performance in controlling grid-connected PEC inverter. The obtained results show least tracking error and fast transient response where low THD and capacitor voltage ripple are obtained.
AB - In this paper, First Order Sliding Mode Control (FOSMC) has been optimally designed for single-phase grid-connected Packed E-Cell (PEC) inverter. PEC is a recent introduced advanced compact inverter topology generates multilevel voltage while capacitors are balanced using the redundant switching states. Therefore, the capacitor voltage balancing is no longer required to be assumed in the grid-connected controller. According to the proposed FOSMC, the sign function is replaced by saturation function to mitigate the chattering phenomenon and improve the controller performance. Afterwards, FOSMC weighting factors are optimized by Artificial Bee Colony (ABC) algorithm to compensate the saturation function error. The proposed OFOSMC has been evaluated by simulation and experimental analyses under both steady and variable conditions to investigate its performance in controlling grid-connected PEC inverter. The obtained results show least tracking error and fast transient response where low THD and capacitor voltage ripple are obtained.
KW - Artificial Bee Colony
KW - First Order Sliding Mode Control
KW - Grid-Connected Inverter Applications
KW - Optimized First Order Sliding Mode Control
KW - Power Quality
KW - Single-Phase Packed E-Cell (PEC) Inverter
UR - https://www.scopus.com/pages/publications/85076735997
U2 - 10.1109/ECCE.2019.8913100
DO - 10.1109/ECCE.2019.8913100
M3 - Contribution to conference proceedings
AN - SCOPUS:85076735997
T3 - 2019 IEEE Energy Conversion Congress and Exposition, ECCE 2019
SP - 2269
EP - 2273
BT - 2019 IEEE Energy Conversion Congress and Exposition, ECCE 2019
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 11th Annual IEEE Energy Conversion Congress and Exposition, ECCE 2019
Y2 - 29 September 2019 through 3 October 2019
ER -