TY - GEN
T1 - Porosity evaluation in compacted and sintered parts using the micro-tomography and metallography techniques
AU - Letenneur, M.
AU - Brailovski, V.
AU - Moravej, M.
AU - Aguirre, L.
N1 - Publisher Copyright:
© 2018 Metal Powder Industries Federation.
PY - 2018
Y1 - 2018
N2 - A Nikon XTH-225 X-ray computerized tomography system (micro-CT) was used to evaluate the porosity of compacted and sintered powder metallurgy components. A 60 mm diameter - 4 mm wall thickness typical midsize component was scanned entirely and then fragmented to 1/4th, 1/16th and 1/32nd of its original size, in order to improve its scanning resolution from 56 μm to 20, 15 and 5 μm, respectively. To optimize the image treatment parameters (grey-level threshold), the Archimedes' measurements and the metallography analyses were concurrently carried out. The dimensions, morphology and distribution of processing-induced pores have been evaluated and a relation between the micro-CT resolution and the detectable level of porosity was established. It was therefore demonstrated that computerized tomography represents an appropriate technique for identification and quantification of processing-induced porosity, and therefore, can be used for process optimization.
AB - A Nikon XTH-225 X-ray computerized tomography system (micro-CT) was used to evaluate the porosity of compacted and sintered powder metallurgy components. A 60 mm diameter - 4 mm wall thickness typical midsize component was scanned entirely and then fragmented to 1/4th, 1/16th and 1/32nd of its original size, in order to improve its scanning resolution from 56 μm to 20, 15 and 5 μm, respectively. To optimize the image treatment parameters (grey-level threshold), the Archimedes' measurements and the metallography analyses were concurrently carried out. The dimensions, morphology and distribution of processing-induced pores have been evaluated and a relation between the micro-CT resolution and the detectable level of porosity was established. It was therefore demonstrated that computerized tomography represents an appropriate technique for identification and quantification of processing-induced porosity, and therefore, can be used for process optimization.
UR - https://www.scopus.com/pages/publications/85072845671
M3 - Contribution to conference proceedings
AN - SCOPUS:85072845671
T3 - Advances in Powder Metallurgy and Particulate Materials - 2018: Proceedings of the 2018 International Conference on Powder Metallurgy and Particulate Material, POWDERMET 2018
SP - 835
EP - 844
BT - Advances in Powder Metallurgy and Particulate Materials - 2018
PB - Metal Powder Industries Federation
T2 - 2018 International Conference on Powder Metallurgy and Particulate Material, POWDERMET 2018
Y2 - 17 June 2018 through 20 June 2018
ER -