TY - GEN
T1 - PWM Sensor-less Balancing Technique for the Fifteen-Level PUC Converter
AU - Ounejjar, Youssef
AU - El Gadari, Ayoub
AU - Abarzadeh, Mostafa
AU - Al-Haddad, Kamal
N1 - Publisher Copyright:
© 2018 IEEE.
PY - 2018/12/31
Y1 - 2018/12/31
N2 - In this paper, a novel PWM technique insuring the self-balancing of the capacitors voltages has been proposed for the attained nine-level packed U cells (PUC) converter. In the traditional fifteen-level operation, the capacitors voltages have to be maintained around their references using a state variable feedback which requires three sensors, two for the capacitors voltages and one for the load current. By applying the proposed PWM technique to the fifteen-level PUC converter, self-balancing of the capacitors voltages is attained, which results in the proposed nine-level converter. The proposed balancing technique is achieved without any closed loop regulation or sensors. The proposed concept has been verified by mean of simulations performed in the Matlab Simulink environments. Simulation results show that even under severe DC bus voltage and load parameters variations, the capacitors voltages remains around their required values. Harmonics contents of load current depend on the modulating signal frequency. Moreover, even under low frequencies, the total harmonics distortion remains reduced.
AB - In this paper, a novel PWM technique insuring the self-balancing of the capacitors voltages has been proposed for the attained nine-level packed U cells (PUC) converter. In the traditional fifteen-level operation, the capacitors voltages have to be maintained around their references using a state variable feedback which requires three sensors, two for the capacitors voltages and one for the load current. By applying the proposed PWM technique to the fifteen-level PUC converter, self-balancing of the capacitors voltages is attained, which results in the proposed nine-level converter. The proposed balancing technique is achieved without any closed loop regulation or sensors. The proposed concept has been verified by mean of simulations performed in the Matlab Simulink environments. Simulation results show that even under severe DC bus voltage and load parameters variations, the capacitors voltages remains around their required values. Harmonics contents of load current depend on the modulating signal frequency. Moreover, even under low frequencies, the total harmonics distortion remains reduced.
KW - PWM technique
KW - multilevel converters
KW - packed U cells
KW - self balancing
UR - https://www.scopus.com/pages/publications/85061903883
U2 - 10.1109/EPEC.2018.8598443
DO - 10.1109/EPEC.2018.8598443
M3 - Contribution to conference proceedings
AN - SCOPUS:85061903883
T3 - 2018 IEEE Electrical Power and Energy Conference, EPEC 2018
BT - 2018 IEEE Electrical Power and Energy Conference, EPEC 2018
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2018 IEEE Electrical Power and Energy Conference, EPEC 2018
Y2 - 10 October 2018 through 11 October 2018
ER -