Reflect: Rectified Flows for Efficient Brain Anomaly Correction Transport

Résultats de recherche: Chapitre dans un livre, rapport, actes de conférenceParticipation à un ouvrage collectif lié à un colloque ou une conférenceRevue par des pairs

Résumé

Unsupervised anomaly detection (UAD) in brain imaging is crucial for identifying pathologies without the need for labeled data. However, accurately localizing anomalies remains challenging due to the intricate structure of brain anatomy and the scarcity of abnormal examples. In this work, we introduce Reflect, a novel framework that leverages rectified flows to establish a direct, linear trajectory for correcting abnormal MR images toward a normal distribution. By learning a straight, one-step correction transport map, our method efficiently corrects brain anomalies and can precisely localize anomalies by detecting discrepancies between anomalous input and corrected counterpart. In contrast to the diffusion-based UAD models, which require iterative stochastic sampling, rectified flows provide a direct transport map, enabling single-step inference. Extensive experiments on popular UAD brain segmentation benchmarks demonstrate that Reflect significantly outperforms state-of-the-art unsupervised anomaly detection methods. The code is available at https://github.com/farzad-bz/REFLECT.

langue originaleAnglais
titreMedical Image Computing and Computer Assisted Intervention, MICCAI 2025 - 28th International Conference, Proceedings
rédacteurs en chefJames C. Gee, Jaesung Hong, Carole H. Sudre, Polina Golland, Daniel C. Alexander, Juan Eugenio Iglesias, Archana Venkataraman, Jong Hyo Kim
EditeurSpringer Science and Business Media Deutschland GmbH
Pages456-466
Nombre de pages11
ISBN (imprimé)9783032049643
Les DOIs
étatPublié - 2026
Evénement28th International Conference on Medical Image Computing and Computer Assisted Intervention, MICCAI 2025 - Daejeon, Corée du Sud
Durée: 23 sept. 202527 sept. 2025

Série de publications

NomLecture Notes in Computer Science
Volume15963 LNCS
ISSN (imprimé)0302-9743
ISSN (Electronique)1611-3349

Conférence

Conférence28th International Conference on Medical Image Computing and Computer Assisted Intervention, MICCAI 2025
Pays/TerritoireCorée du Sud
La villeDaejeon
période23/09/2527/09/25

Empreinte digitale

Voici les principaux termes ou expressions associés à « Reflect: Rectified Flows for Efficient Brain Anomaly Correction Transport ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.

Contient cette citation