Passer à la navigation principale Passer à la recherche Passer au contenu principal

Regional heart motion abnormality detection via information measures and unscented Kalman filtering

  • GE Healthcare
  • Western University

Résultats de recherche: Chapitre dans un livre, rapport, actes de conférence › Participation à un ouvrage collectif lié à un colloque ou une conférence › Revue par des pairs

18 Citations (Scopus)

Résumé

This study investigates regional heart motion abnormality detection using various classifier features with Shannon's Differential Entropy (SDE). Rather than relying on elementary measurements or a fixed set of moments, the SDE measures global distribution information and, as such, has more discriminative power in classifying distributions. Based on functional images, which are subject to noise and segmentation inaccuracies, heart wall motion analysis is acknowledged as a difficult problem and, therefore, incorporation of prior knowledge is desirable to enhance the accuracy. Given noisy data and nonlinear dynamic model to describe the myocardial motion, unscented Kalman filter, a recursive nonlinear Bayesian filter, is devised in this study so as to estimate LV cavity points. Subsequently, a naive Bayes classifier algorithm is constructed from the SDEs of different features in order to automatically detect abnormal functional regions of the myocardium. Using 90x20 segmented LV cavities of short-axis magnetic resonance images obtained from 30 subjects, the experimental analysis carried over 480 myocardial segments demonstrates that the proposed method perform significantly better than other recent methods, and can lead to a promising diagnostic support tool to assist clinicians.

langue originaleAnglais
titreMedical Image Computing and Computer-Assisted Intervention, MICCAI2010 - 13th International Conference, Proceedings
EditeurSpringer Verlag
Pages409-417
Nombre de pages9
EditionPART 1
ISBN (imprimé)3642157041, 9783642157042
Les DOIs
étatPublié - 2010
Modification externeOui
Evénement13th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2010 - Beijing, Chine
Durée: 20 sept. 2010 → 24 sept. 2010

Série de publications

NomLecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
nombrePART 1
Volume6361 LNCS
ISSN (imprimé)0302-9743
ISSN (Electronique)1611-3349

Conférence

Conférence13th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2010
Pays/TerritoireChine
La villeBeijing
période20/09/10 → 24/09/10

Empreinte digitale

Voici les principaux termes ou expressions associés à « Regional heart motion abnormality detection via information measures and unscented Kalman filtering ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.

Citer cette ressource