Passer à la navigation principale Passer à la recherche Passer au contenu principal

Regional heart motion abnormality detection via multiview fusion

  • Kumaradevan Punithakumar
  • , Ismail Ben Ayed
  • , Ali Islam
  • , Aashish Goela
  • , Shuo Li
  • GE Healthcare
  • Western University

Résultats de recherche: Chapitre dans un livre, rapport, actes de conférence › Participation à un ouvrage collectif lié à un colloque ou une conférence › Revue par des pairs

6 Citations (Scopus)

Résumé

This study investigates regional heartmotion abnormality detection viamultiview fusion in cine cardiacMRimages. In contrast to previous methods which rely only on short-axis image sequences, the proposed approach exploits the information from several other long-axis image sequences, namely, 2-chamber, 3-chamber and 4-chamber MR images. Our analysis follows the standard issued by American Heart Association to identify 17 standardized left ventricular segments. The proposed method first computes an initial sequence of correspondingmyocardial points using a nonrigid image registration algorithm within each sequence. Then, these points were mapped to 3D space and tracked using UnscentedKalman Filter (UKS).We propose a maximum likelihood based track-to-track fusion approach to combine UKS tracks from multiple image views. Finally, we use a Shannon’s differential entropy of distributions of potential classifiers obtained from multiview fusion estimates, and a naive Bayes classifier algorithm to automatically detect abnormal functional regions of the myocardium. We proved the benefits of the proposed method by comparing the classification results with and without fusion over 480 regionalmyocardial segments obtained from 30 subjects. The evaluations in comparisons to the ground truth classifications by radiologists showed that the proposed fusion yielded an area-under-the-curve (AUC) of 95.9%, bringing a significant improvement of 3.8% in comparisons to previous methods that use only short-axis images.

Langue originaleAnglais
titreMedical Image Computing and Computer-Assisted Intervention - MICCAI2012 - 15th International Conference, Proceedings
rédacteurs en chefGeorg Langs, Bjoern H. Menze, Antonio Criminisi, Zhuowen Tu, Georg Langs, Le Lu, Bjoern H. Menze, Nicholas Ayache, Hervé Delingette, Albert Montillo, Polina Golland, Kensaku Mori
EditeurSpringer Verlag
Pages527-534
Nombre de pages8
ISBN (imprimé)9783642334177
Les DOIs
ÉtatPublié - 2012
Modification externeOui
Evénement15th International Conference on Medical Image Computing and Computer Assisted Intervention, MICCAI 2012 - Nice, France
Durée: 1 oct. 2012 → 5 oct. 2012

Série de publications

NomLecture Notes in Computer Science
Volume7511 LNCS
ISSN (imprimé)0302-9743
ISSN (Electronique)1611-3349

Conférence

Conférence15th International Conference on Medical Image Computing and Computer Assisted Intervention, MICCAI 2012
Pays/TerritoireFrance
La villeNice
Période1/10/12 → 5/10/12

Classification disciplinaire ASJC Scopus

  • Informatique théorique
  • Informatique générale

Empreinte digitale

Voici les principaux termes ou expressions associés à « Regional heart motion abnormality detection via multiview fusion ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.

Citer cette ressource