N2 - Fine-tuning Large Language Models (LLMs) for clinical Natural Language Processing (NLP) poses significant challenges due to domain gap, limited data, and stringent hardware constraints. In this study, we evaluate four adapter techniques—Adapter, Lightweight, TinyAttention, and Gated Residual Network (GRN) - equivalent to Low-Rank Adaptation (LoRA), for clinical note classification under real-world, resource-constrained conditions. All experiments were conducted on a single NVIDIA Quadro P620 GPU (2 GB VRAM, 512 CUDA cores, 1.386 TFLOPS FP32), limiting batch sizes to ≤ 8 sequences and maximum sequence length to 256 tokens. Our clinical corpus comprises only 580 000 tokens, several orders of magnitude smaller than standard LLM pre-training datasets. We fine-tuned three biomedical pre-trained LLMs (CamemBERT-bio, AliBERT, DrBERT) and two lightweight Transformer models trained from scratch. Results show that 1) adapter structures provide no consistent gains when fine-tuning biomedical LLMs under these constraints, and 2) simpler Transformers, with minimal parameter counts and training times under six hours, outperform adapter-augmented LLMs, which required over 1000 GPU-hours. Among adapters, GRN achieved the best metrics (accuracy, precision, recall, F1 = 0.88). These findings demonstrate that, in low-resource clinical settings with limited data and compute, lightweight Transformers trained from scratch offer a more practical and efficient solution than large LLMs, while GRN remains a viable adapter choice when minimal adaptation is needed.
AB - Fine-tuning Large Language Models (LLMs) for clinical Natural Language Processing (NLP) poses significant challenges due to domain gap, limited data, and stringent hardware constraints. In this study, we evaluate four adapter techniques—Adapter, Lightweight, TinyAttention, and Gated Residual Network (GRN) - equivalent to Low-Rank Adaptation (LoRA), for clinical note classification under real-world, resource-constrained conditions. All experiments were conducted on a single NVIDIA Quadro P620 GPU (2 GB VRAM, 512 CUDA cores, 1.386 TFLOPS FP32), limiting batch sizes to ≤ 8 sequences and maximum sequence length to 256 tokens. Our clinical corpus comprises only 580 000 tokens, several orders of magnitude smaller than standard LLM pre-training datasets. We fine-tuned three biomedical pre-trained LLMs (CamemBERT-bio, AliBERT, DrBERT) and two lightweight Transformer models trained from scratch. Results show that 1) adapter structures provide no consistent gains when fine-tuning biomedical LLMs under these constraints, and 2) simpler Transformers, with minimal parameter counts and training times under six hours, outperform adapter-augmented LLMs, which required over 1000 GPU-hours. Among adapters, GRN achieved the best metrics (accuracy, precision, recall, F1 = 0.88). These findings demonstrate that, in low-resource clinical settings with limited data and compute, lightweight Transformers trained from scratch offer a more practical and efficient solution than large LLMs, while GRN remains a viable adapter choice when minimal adaptation is needed.
KW - LLM
KW - Low-rank adaptation (LoRA)
KW - adapters
KW - cardiac failure
KW - clinical NLP
KW - text classification
UR - https://www.scopus.com/pages/publications/105009265089
U2 - 10.1109/ACCESS.2025.3582037
DO - 10.1109/ACCESS.2025.3582037
M3 - Journal Article
AN - SCOPUS:105009265089
SN - 2169-3536
VL - 13
SP - 109365
EP - 109377
JO - IEEE Access
JF - IEEE Access
ER -