Résumé
The normal incidence sound transmission loss (nSTL) is an important indicator to assess the sound insulation property of acoustic materials. The apparatus consists of a finite length rigid walled impedance tube with circularly shaped and uniform inner cross-section. The tube features a loudspeaker at one end and a movable piston at the other end. The loudspeaker is used to generate a plane wave field in the impedance tube. There are two microphones flush mounted upstream the test sample and one microphone flush mounted on the rigid end. Next, a 20-mm thick step discontinuity seeing as a non-symmetrical sample is tested and compared to the standard 4M2L method and 3M-TMTC method. One can note that similar results are obtained between the 3M2L and 4M2L methods, however 4M2L is noisier compared to 3M2L.
| Langue originale | Anglais |
|---|---|
| Pages (de - à) | 16-17 |
| Nombre de pages | 2 |
| Revue | Canadian Acoustics - Acoustique Canadienne |
| Volume | 39 |
| Numéro de publication | 3 |
| État | Publié - sept. 2011 |
| Modification externe | Oui |
Classification disciplinaire ASJC Scopus
- Acoustique et ultrasons
Empreinte digitale
Voici les principaux termes ou expressions associés à « Three-microphone two-cavity method for measuring sound transmission loss in a modified impedance tube ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.Citer cette ressource