Toward a better noninvasive assessment of preejection period: A novel automatic algorithm for B-point detection and correction on thoracic impedance cardiogram

  • Mohamad Forouzanfar
  • , Fiona C. Baker
  • , Massimiliano de Zambotti
  • , Corey McCall
  • , Laurent Giovangrandi
  • , Gregory T.A. Kovacs
  • SRI International
  • Stanford University

Résultats de recherche: Contribution à un journal › Article publié dans une revue, révisé par les pairs › Revue par des pairs

41 Citations (Scopus)

Résumé

Impedance cardiography is the most common clinically validated, noninvasive method for determining the timing of the opening of the aortic valve, an important event used for measuring preejection period, which reflects sympathetic beta-adrenergic influences on the heart. Automatic detection of the exact time of the opening of the aortic valve (B point on the impedance cardiogram) has proven to be challenging as its appearance varies between and within individuals and may manifest as a reversal, inflection, or rapid slope change of the thoracic impedance derivative's (dZ/dt) rapid rise. Here, a novel automatic algorithm is proposed for the detection of the B point by finding the main rapid rise of the dZ/dt signal, which is due to blood ejection. Several conditions based on zero crossings, minima, and maxima of the dZ/dt signal and its derivatives are considered to reject any unwanted noise and artifacts and select the true B-point location. The detected B-point locations are then corrected by modeling the B-point time data using forward and reverse autoregressive models. The proposed algorithm is validated against expert-detected B points and is compared with different conventional methods; it significantly outperforms them by at least 54% in mean error, 30% in mean absolute error, and 27% in standard deviation of error. This algorithm can be adopted in ambulatory studies requiring beat-to-beat evaluation of cardiac hemodynamic parameters over extended time periods where expert scoring is not feasible.

Langue originaleAnglais
Numéro d'articlee13072
RevuePsychophysiology
Volume55
Numéro de publication8
Les DOIs
ÉtatPublié - août 2018
Modification externeOui

Classification disciplinaire ASJC Scopus

  • Neuropsychologie et psychologie physiologique
  • Physiologie
  • Psychologie expérimentale et cognitive
  • Physiologie (médicale)

Empreinte digitale

Voici les principaux termes ou expressions associés à « Toward a better noninvasive assessment of preejection period: A novel automatic algorithm for B-point detection and correction on thoracic impedance cardiogram ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.

Citer cette ressource