Passer à la navigation principale Passer à la recherche Passer au contenu principal

Validation of Automatically Quantified Swim Stroke Mechanics Using an Inertial Measurement Unit in Paralympic Athletes

  • Matthew Slopecki
  • , Mathieu Charbonneau
  • , Jean Michel Lavallière
  • , Julie N. Côté
  • , Julien Clément
  • McGill University
  • Institut national du sport du Québec (INS Québec)
  • Swimming Natation Canada

Résultats de recherche: Contribution à un journal › Article publié dans une revue, révisé par les pairs › Revue par des pairs

12 Citations (Scopus)

Résumé

Biomechanics and training load monitoring are important for performance evaluation and injury prevention in elite swimming. Monitoring of performance and swim stroke parameters is possible with inertial measurement units (IMU) but has not been validated in para-swimmers. The purpose of this study was to validate a single IMU-based system to accurately estimate pool-swam lap time, stroke count (SC), stroke duration, instantaneous stroke rate (ISR), and distance per stroke (DPS). Eight Paralympic athletes completed 4 × 50 m swims with an IMU worn on the sacrum. Strokes cycles were identified using a zero-crossing algorithm on the medio-lateral (freestyle and backstroke) or forward-backward (butterfly and breaststroke) instantaneous velocity data. Video-derived metrics were estimated using Dartfish and Kinovea. Agreement analyses, including Bland–Altman and Intraclass Correlation Coefficient (ICC), were performed on all outcome variables. SC Bland–Altman bias was 0.13 strokes, and ICC was 0.97. ISR Bland–Altman biases were within 1.5 strokes/min, and ICCs ranged from 0.26 to 0.96. DPS Bland–Altman biases were within 0.20 m, and ICCs ranged from 0.39 to 0.93. A single-IMU system can provide highly valid performance and swim stroke monitoring data for elite para-swimmers for the majority of strokes, with the exception of backstroke. Future work should improve bilateral stroke detection algorithms in this population.

Langue originaleAnglais
Numéro d'article15
RevueBioengineering
Volume11
Numéro de publication1
Les DOIs
ÉtatPublié - janv. 2024

SDG des Nations Unies

Ce résultat contribue à ou aux Objectifs de développement durable suivants

  1. SDG 3 – Bonne santé et bien-être
    SDG 3 – Bonne santé et bien-être

Classification disciplinaire ASJC Scopus

  • Bio-ingénierie

Empreinte digitale

Voici les principaux termes ou expressions associés à « Validation of Automatically Quantified Swim Stroke Mechanics Using an Inertial Measurement Unit in Paralympic Athletes ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.

Citer cette ressource