TY - GEN
T1 - Force relaxation and sprinback of novel elastic orthopedic cables
AU - Canet, Fanny
AU - Baril, Yannick
AU - Brailovski, Vladimir
AU - Petit, Yvan
AU - Bissonnette, Guillaume
AU - Laflamme, G. Yves
PY - 2011
Y1 - 2011
N2 - Cerclage cables have proven to be very useful in the orthopedic field for bones stabilization and plate fixation but the initial enthusiasm for metallic cables has declined with their high complication rates. Metal materials provide limited elastic deformation compromising their ability to maintain compression. This study compares the mechanical properties of new elastic cables with cobalt-chrome and stainless-steel cables. Methods: Stainless-steel, cobalt-chrome, nylon and nickel-titanium cables were first loaded up to 356 N, then elongation was maintained for 12 hours, next unloaded and finally reloaded to failure. Initial elongation (%), Relative force relaxation (% loss of initial load after a 12h), elastic springback (%) and force to failure (N) were extracted from force-elongation curves. Findings: Initial elongation was the highest for nylon cables (9%), followed by the nickel-titanium (4%) and both metallic cables (0.3%). During 12 hours, no relaxation was observed for the nickel-titanium and the cobalt-chrome cables, whereas 28 and 45% of the tension was lost respectively for the stainless-steel and the nylon cables. The elastic springback of the nickel-titanium and nylon cables (4.4 and 4.7% respectively) was 20 times higher than that of the stainless-steel and cobalt-chrome cables (0.12 and 0.16% respectively). The force to failure of the stainless steel and cobalt-chrome cables was twice that of the nickel-titanium cables. Interpretation: Multi-braided stainless-steel and cobalt-chrome cables have a high-stiffness with limited ability to tolerate displacement, leading to early cable loosening. Novel low-stiffness cables made of nylon or nickel-titanium offer significant elastic springback improving binding stability.
AB - Cerclage cables have proven to be very useful in the orthopedic field for bones stabilization and plate fixation but the initial enthusiasm for metallic cables has declined with their high complication rates. Metal materials provide limited elastic deformation compromising their ability to maintain compression. This study compares the mechanical properties of new elastic cables with cobalt-chrome and stainless-steel cables. Methods: Stainless-steel, cobalt-chrome, nylon and nickel-titanium cables were first loaded up to 356 N, then elongation was maintained for 12 hours, next unloaded and finally reloaded to failure. Initial elongation (%), Relative force relaxation (% loss of initial load after a 12h), elastic springback (%) and force to failure (N) were extracted from force-elongation curves. Findings: Initial elongation was the highest for nylon cables (9%), followed by the nickel-titanium (4%) and both metallic cables (0.3%). During 12 hours, no relaxation was observed for the nickel-titanium and the cobalt-chrome cables, whereas 28 and 45% of the tension was lost respectively for the stainless-steel and the nylon cables. The elastic springback of the nickel-titanium and nylon cables (4.4 and 4.7% respectively) was 20 times higher than that of the stainless-steel and cobalt-chrome cables (0.12 and 0.16% respectively). The force to failure of the stainless steel and cobalt-chrome cables was twice that of the nickel-titanium cables. Interpretation: Multi-braided stainless-steel and cobalt-chrome cables have a high-stiffness with limited ability to tolerate displacement, leading to early cable loosening. Novel low-stiffness cables made of nylon or nickel-titanium offer significant elastic springback improving binding stability.
UR - https://www.scopus.com/pages/publications/84862274506
U2 - 10.1109/IEMBS.2011.6091425
DO - 10.1109/IEMBS.2011.6091425
M3 - Contribution to conference proceedings
C2 - 22255648
AN - SCOPUS:84862274506
SN - 9781424441211
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 5758
EP - 5761
BT - 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
T2 - 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
Y2 - 30 August 2011 through 3 September 2011
ER -