Force relaxation and sprinback of novel elastic orthopedic cables

  • Research Center - Hôpital du Sacré-Coeur de Montréal
  • École de technologie supérieure
  • University of Montreal

Résultats de recherche: Chapitre dans un livre, rapport, actes de conférence › Participation à un ouvrage collectif lié à un colloque ou une conférence › Revue par des pairs

4 Citations (Scopus)

Résumé

Cerclage cables have proven to be very useful in the orthopedic field for bones stabilization and plate fixation but the initial enthusiasm for metallic cables has declined with their high complication rates. Metal materials provide limited elastic deformation compromising their ability to maintain compression. This study compares the mechanical properties of new elastic cables with cobalt-chrome and stainless-steel cables. Methods: Stainless-steel, cobalt-chrome, nylon and nickel-titanium cables were first loaded up to 356 N, then elongation was maintained for 12 hours, next unloaded and finally reloaded to failure. Initial elongation (%), Relative force relaxation (% loss of initial load after a 12h), elastic springback (%) and force to failure (N) were extracted from force-elongation curves. Findings: Initial elongation was the highest for nylon cables (9%), followed by the nickel-titanium (4%) and both metallic cables (0.3%). During 12 hours, no relaxation was observed for the nickel-titanium and the cobalt-chrome cables, whereas 28 and 45% of the tension was lost respectively for the stainless-steel and the nylon cables. The elastic springback of the nickel-titanium and nylon cables (4.4 and 4.7% respectively) was 20 times higher than that of the stainless-steel and cobalt-chrome cables (0.12 and 0.16% respectively). The force to failure of the stainless steel and cobalt-chrome cables was twice that of the nickel-titanium cables. Interpretation: Multi-braided stainless-steel and cobalt-chrome cables have a high-stiffness with limited ability to tolerate displacement, leading to early cable loosening. Novel low-stiffness cables made of nylon or nickel-titanium offer significant elastic springback improving binding stability.

Langue originaleAnglais
titre33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
Pages5758-5761
Nombre de pages4
Les DOIs
ÉtatPublié - 2011
Evénement33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011 - Boston, MA, Etats-Unis
Durée: 30 août 2011 → 3 sept. 2011

Série de publications

NomProceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
ISSN (imprimé)1557-170X

Conférence

Conférence33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
Pays/TerritoireEtats-Unis
La villeBoston, MA
Période30/08/11 → 3/09/11

Classification disciplinaire ASJC Scopus

  • Traitement du signal
  • Ingénierie biomédicale
  • Vision par ordinateur et reconnaissance de formes
  • Informatique médicale

Empreinte digitale

Voici les principaux termes ou expressions associés à « Force relaxation and sprinback of novel elastic orthopedic cables ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.

Citer cette ressource