Limb-sparing in dogs using patient-specific, three-dimensional-printed endoprosthesis for distal radial osteosarcoma: A pilot study

  • Bernard Séguin
  • , Chris Pinard
  • , Bertrand Lussier
  • , Deanna Williams
  • , Lynn Griffin
  • , Brendan Podell
  • , Sebastian Mejia
  • , Anatolie Timercan
  • , Yvan Petit
  • , Vladimir Brailovski
  • Colorado State University
  • University of Montreal
  • École de technologie supérieure

Research output: Contribution to journal › Journal Article › peer-review

34 Citations (Scopus)

Abstract

Limb-sparing for distal radial osteosarcoma has a high rate of complications. Using personalized three-dimensional (3D)-printed implants might improve outcome. The goals of this study were to optimize use of patient-specific, 3D-printed endoprostheses for limb-sparing in dogs in the clinical environment and to report the outcome. This was a pilot study where five client-owned dogs were enrolled. Computed tomography (CT) of the thoracic limbs was performed, which was used to create patient-specific endoprostheses and cutting guides, and repeated on the day of surgery. Intra-arterial (IA) carboplatin was introduced in the clinical management. Limb-sparing was performed. Outcome measures were time required to produce the endoprosthesis and cutting guide, fit between cutting guide and endoprosthesis with host bones, gait analysis, size of the tumour, percent tumour necrosis, complications, disease-free interval (DFI) and survival time (ST). Four dogs received IA carboplatin. Excessive tumour growth between planning CT and surgery did not occur in any dog. The interval between the CT and surgery ranged from 14 to 70 days. Fit between the cutting-guide and endoprosthesis with the host bones was good to excellent. At least one complication occurred in all dogs. Two dogs were euthanized with STs of 192 and 531 days. The other dogs were alive with a follow up of 534 to 575 days. IA chemotherapy is a promising strategy to minimize the risk of excessive tumour growth while waiting for the endoprosthesis and cutting-guide to be made. The design of the cutting-guide was critical for best fit of the endoprosthesis with host bones.

Original languageEnglish
Pages (from-to)92-104
Number of pages13
JournalVeterinary and Comparative Oncology
Volume18
Issue number1
DOIs
Publication statusPublished - 1 Mar 2020

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • bone
  • cancer
  • canine
  • surgery

ASJC Scopus subject areas

  • General Veterinary

Fingerprint

Dive into the research topics of 'Limb-sparing in dogs using patient-specific, three-dimensional-printed endoprosthesis for distal radial osteosarcoma: A pilot study'. These topics are generated from the title and abstract of the publication. Together, they form a unique fingerprint.

Cite this