Passer à la navigation principale Passer à la recherche Passer au contenu principal

Limb-sparing in dogs using patient-specific, three-dimensional-printed endoprosthesis for distal radial osteosarcoma: A pilot study

  • Bernard Séguin
  • , Chris Pinard
  • , Bertrand Lussier
  • , Deanna Williams
  • , Lynn Griffin
  • , Brendan Podell
  • , Sebastian Mejia
  • , Anatolie Timercan
  • , Yvan Petit
  • , Vladimir Brailovski
  • Colorado State University
  • University of Montreal
  • École de technologie supérieure

Résultats de recherche: Contribution à un journal › Article publié dans une revue, révisé par les pairs › Revue par des pairs

34 Citations (Scopus)

Résumé

Limb-sparing for distal radial osteosarcoma has a high rate of complications. Using personalized three-dimensional (3D)-printed implants might improve outcome. The goals of this study were to optimize use of patient-specific, 3D-printed endoprostheses for limb-sparing in dogs in the clinical environment and to report the outcome. This was a pilot study where five client-owned dogs were enrolled. Computed tomography (CT) of the thoracic limbs was performed, which was used to create patient-specific endoprostheses and cutting guides, and repeated on the day of surgery. Intra-arterial (IA) carboplatin was introduced in the clinical management. Limb-sparing was performed. Outcome measures were time required to produce the endoprosthesis and cutting guide, fit between cutting guide and endoprosthesis with host bones, gait analysis, size of the tumour, percent tumour necrosis, complications, disease-free interval (DFI) and survival time (ST). Four dogs received IA carboplatin. Excessive tumour growth between planning CT and surgery did not occur in any dog. The interval between the CT and surgery ranged from 14 to 70 days. Fit between the cutting-guide and endoprosthesis with the host bones was good to excellent. At least one complication occurred in all dogs. Two dogs were euthanized with STs of 192 and 531 days. The other dogs were alive with a follow up of 534 to 575 days. IA chemotherapy is a promising strategy to minimize the risk of excessive tumour growth while waiting for the endoprosthesis and cutting-guide to be made. The design of the cutting-guide was critical for best fit of the endoprosthesis with host bones.

Langue originaleAnglais
Pages (de - à)92-104
Nombre de pages13
RevueVeterinary and Comparative Oncology
Volume18
Numéro de publication1
Les DOIs
ÉtatPublié - 1 mars 2020

SDG des Nations Unies

Ce résultat contribue à ou aux Objectifs de développement durable suivants

  1. SDG 3 – Bonne santé et bien-être
    SDG 3 – Bonne santé et bien-être

Classification disciplinaire ASJC Scopus

  • Sciences vétérinaires générales

Empreinte digitale

Voici les principaux termes ou expressions associés à « Limb-sparing in dogs using patient-specific, three-dimensional-printed endoprosthesis for distal radial osteosarcoma: A pilot study ». Ces libellés thématiques sont générés à partir du titre et du résumé de la publication. Ensemble, ils forment une empreinte digitale unique.

Citer cette ressource