T1 - Ln-vitro testing of a new superelastic sternum closure component
AU - Baril, Y.
AU - Brailovski, V.
AU - Chartrand, M.
AU - Terriault, P.
AU - Cartier, R.
PY - 2008
Y1 - 2008
N2 - Bone binding using cable or wire-like components made of stainless steel or Co-Cr alloys are subject to fixation loosening, resulting in fracture dehiscence. A tubular braided structure made of superelastic Ti-Ni alloy, which tends towards a flat form when bent around the bone, can solve this problem. The superelastic tubular component maintains positive pressure on the closure site throughout the healing process, even after an abrupt relative movement of the connected bones, thus increasing the overall stability of the fixation. Furthermore, the new device reduces the interface pressure between the bone and the binding component by increasing the contact area. To install the device, a metallic sleeve is crimped, and retains both ends of the cable with a specially designed installation tool. The new bone binding component is also fatigue-resistant. As an example, a binding component made of 24 x 00.1 mm Ti-Ni filaments can sustain about 1000 cycles of strain-controlled fatigue testing between 4 and 8% of relative elongation. In-vitro comparative testing of the new binding component and conventional wire suture are performed on a customary testing bench, where sutures are installed directly by a surgeon. The bench can apply complex planar loading, imitating real post-operative conditions of the closed sternum. The results of the comparative testing show that the new system results in a significant gain in the residual compressive force between sternum halves following either a disruption event (coughing), or a long-term service (deep breathing). Finally, the metallic sleeve is found to be capable of sustaining one and a half times the maximum theoretical force applied on a sternum site during a coughing fit.
AB - Bone binding using cable or wire-like components made of stainless steel or Co-Cr alloys are subject to fixation loosening, resulting in fracture dehiscence. A tubular braided structure made of superelastic Ti-Ni alloy, which tends towards a flat form when bent around the bone, can solve this problem. The superelastic tubular component maintains positive pressure on the closure site throughout the healing process, even after an abrupt relative movement of the connected bones, thus increasing the overall stability of the fixation. Furthermore, the new device reduces the interface pressure between the bone and the binding component by increasing the contact area. To install the device, a metallic sleeve is crimped, and retains both ends of the cable with a specially designed installation tool. The new bone binding component is also fatigue-resistant. As an example, a binding component made of 24 x 00.1 mm Ti-Ni filaments can sustain about 1000 cycles of strain-controlled fatigue testing between 4 and 8% of relative elongation. In-vitro comparative testing of the new binding component and conventional wire suture are performed on a customary testing bench, where sutures are installed directly by a surgeon. The bench can apply complex planar loading, imitating real post-operative conditions of the closed sternum. The results of the comparative testing show that the new system results in a significant gain in the residual compressive force between sternum halves following either a disruption event (coughing), or a long-term service (deep breathing). Finally, the metallic sleeve is found to be capable of sustaining one and a half times the maximum theoretical force applied on a sternum site during a coughing fit.
UR - https://www.scopus.com/pages/publications/65649102282
M3 - Contribution to conference proceedings
AN - SCOPUS:65649102282
SN - 9780871707222
T3 - SMST-2007 - Proceedings of the International Conference on Shape Memory and Superelastic Technologies
SP - 497
EP - 506
BT - SMST-2007 - Proceedings of the International Conference on Shape Memory and Superelastic Technologies
PB - ASM International
T2 - International Conference on Shape Memory and Superelastic Technologies, SMST-2007
Y2 - 2 December 2007 through 5 December 2007
ER -