Skip to main navigation Skip to search Skip to main content

Ln-vitro testing of a new superelastic sternum closure component

  • École de technologie supérieure
  • University of Montreal

Research output: Contribution to Book/Report types › Contribution to conference proceedings › peer-review

1 Citation (Scopus)

Abstract

Bone binding using cable or wire-like components made of stainless steel or Co-Cr alloys are subject to fixation loosening, resulting in fracture dehiscence. A tubular braided structure made of superelastic Ti-Ni alloy, which tends towards a flat form when bent around the bone, can solve this problem. The superelastic tubular component maintains positive pressure on the closure site throughout the healing process, even after an abrupt relative movement of the connected bones, thus increasing the overall stability of the fixation. Furthermore, the new device reduces the interface pressure between the bone and the binding component by increasing the contact area. To install the device, a metallic sleeve is crimped, and retains both ends of the cable with a specially designed installation tool. The new bone binding component is also fatigue-resistant. As an example, a binding component made of 24 x 00.1 mm Ti-Ni filaments can sustain about 1000 cycles of strain-controlled fatigue testing between 4 and 8% of relative elongation. In-vitro comparative testing of the new binding component and conventional wire suture are performed on a customary testing bench, where sutures are installed directly by a surgeon. The bench can apply complex planar loading, imitating real post-operative conditions of the closed sternum. The results of the comparative testing show that the new system results in a significant gain in the residual compressive force between sternum halves following either a disruption event (coughing), or a long-term service (deep breathing). Finally, the metallic sleeve is found to be capable of sustaining one and a half times the maximum theoretical force applied on a sternum site during a coughing fit.

Original languageEnglish
Title of host publicationSMST-2007 - Proceedings of the International Conference on Shape Memory and Superelastic Technologies
PublisherASM International
Pages497-506
Number of pages10
ISBN (Print)9780871707222
Publication statusPublished - 2008
EventInternational Conference on Shape Memory and Superelastic Technologies, SMST-2007 - Tsukuba, Japan
Duration: 2 Dec 2007 → 5 Dec 2007

Publication series

NameSMST-2007 - Proceedings of the International Conference on Shape Memory and Superelastic Technologies

Conference

ConferenceInternational Conference on Shape Memory and Superelastic Technologies, SMST-2007
Country/TerritoryJapan
CityTsukuba
Period2/12/07 → 5/12/07